Page 6 highlights
13. Secure damper plate with two screws removed in Step 1. A B A. Damper plate B. Screws Roof Venting Installation Only 1. Repeat Step 1 from "Wall Venting Installation Only." 2. Repeat Step 2 from "Wall Venting Installation Only." 3. Repeat Step 3 from "Wall Venting Installation Only." 4. Repeat Step 4 from "Wall Venting Installation Only." 5. Repeat Step 5 from "Wall Venting Installation Only." 6. Using diagonal wire cutting pliers, gently snip out the rectangular vent covers on the damper plate at the perforations. A 8. Reconnect the blower motor wire into the connector. 9. Reattach the two blower screws into the recessed holes in the back of the microwave. 10. Check to make sure the two screws are secured properly in the blower motor screw holes, so that the motor cannot move. 11. Return the damper plate to its original horizontal position. A A. Damper plate 12. Secure damper plate with two screws removed in Step 1. A B A. Rectangular vent covers B. Diagonal wire cutting pliers 7. Lower blower motor back into microwave oven. Exhaust ports face the top of microwave oven. A B A. Damper plate B. Screws A. Exhaust port IMPORTANT: If blower motor is not positioned with flat side facing the back of the microwave oven (as shown), performance will be poor. 6