Maytag MMV1175 Installation Instructions - Page 6

Roof Venting Installation Only

Page 6 highlights

13. Secure damper plate with two screws removed in Step 1. A B A. Damper plate B. Screws Roof Venting Installation Only 1. Repeat Step 1 from "Wall Venting Installation Only." 2. Repeat Step 2 from "Wall Venting Installation Only." 3. Repeat Step 3 from "Wall Venting Installation Only." 4. Repeat Step 4 from "Wall Venting Installation Only." 5. Repeat Step 5 from "Wall Venting Installation Only." 6. Using diagonal wire cutting pliers, gently snip out the rectangular vent covers on the damper plate at the perforations. A 8. Reconnect the blower motor wire into the connector. 9. Reattach the two blower screws into the recessed holes in the back of the microwave. 10. Check to make sure the two screws are secured properly in the blower motor screw holes, so that the motor cannot move. 11. Return the damper plate to its original horizontal position. A A. Damper plate 12. Secure damper plate with two screws removed in Step 1. A B A. Rectangular vent covers B. Diagonal wire cutting pliers 7. Lower blower motor back into microwave oven. Exhaust ports face the top of microwave oven. A B A. Damper plate B. Screws A. Exhaust port IMPORTANT: If blower motor is not positioned with flat side facing the back of the microwave oven (as shown), performance will be poor. 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

6
13.
Secure damper plate with two screws removed in Step 1.
Roof Venting Installation Only
1.
Repeat Step 1 from “Wall Venting Installation Only.”
2.
Repeat Step 2 from “Wall Venting Installation Only.”
3.
Repeat Step 3 from “Wall Venting Installation Only.”
4.
Repeat Step 4 from “Wall Venting Installation Only.”
5.
Repeat Step 5 from “Wall Venting Installation Only.”
6.
Using diagonal wire cutting pliers, gently snip out the
rectangular vent covers on the damper plate at the
perforations.
7.
Lower blower motor back into microwave oven. Exhaust
ports face the top of microwave oven.
IMPORTANT:
If blower motor is not positioned with flat
side facing the back of the microwave oven (as shown),
performance will be poor.
8.
Reconnect the blower motor wire into the connector.
9.
Reattach the two blower screws into the recessed holes in
the back of the microwave.
10.
Check to make sure the two screws are secured properly
in the blower motor screw holes, so that the motor cannot
move.
11.
Return the damper plate to its original horizontal position.
12.
Secure damper plate with two screws removed in Step 1.
A
B
A. Damper plate
B. Screws
B
A
A. Rectangular vent covers
B. Diagonal wire cutting pliers
A
A. Exhaust port
A. Damper plate
A
A. Damper plate
B. Screws
A
B