70: Standby-power digital +3.3V abnormality 71: Standby-power +5V abnormality 72: Main-power panel +12V abnormality 73: Main-power +2.5V abnormality 74: Main-power +1.8V abnormality 75: Standby-power analog +3.3V abnormality 76: Main-power analog +3.3V abnormality 77: Main-power digital +3.3V abnormality 78: Power-good signal +4.2V abnormality 80: Cooling fan-1 abnormality 81: Cooling fan-2 abnormality 82: Cooling fan-3 abnormality 90: Inverter abnormality  The byte data 70 is encoded as ASCII characters '7' and '0' (37h and 30h). ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.5 "Check code" for a BCC calculation. Delimiter CR (0Dh): End of packet 12. Serial No. & Model Name Read 12.1 Serial No. Read This command is used in order to read a serial number. 1) The controller requests the monitor to read a serial number. Header Message Check code SOH-'0'-Monitor ID-'0'-'A'-'0'-'6' STX-'C'-'2'-'1'-'6'-ETX BCC Delimiter CR Header SOH (01h): Start Of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID which you want to get serial number. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'A' (41h): Message type is "Command". '0'-'6'(30h, 36h): Message length Message STX (02h): Start of Message 'C'-'2'-'1'-'6' (43h, 32h, 31h, 36h): Serial No. command ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.5 "Check code" for a BCC calculation. Delimiter CR (0Dh): End of packet 2) The monitor replies the serial No. data to the controller. Header SOH-'0'-'0'-Monitor ID-'B'-N-N Message STX-'C'-'3'-'1'-'6'Data(0)-Data(1)---Data(n)-ETX Check code BCC Delimiter CR Header SOH (01h): Start Of Header '0' (30h): Reserved '0' (30h): Message receiver is the controller. Monitor ID: Indicate a replying Monitor ID. Ex.) When this byte is set to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is "Command reply". N-N: Message length (29/40)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

(29/40)
70: Standby-power digital +3.3V abnormality
71: Standby-power +5V abnormality
72: Main-power panel +12V abnormality
73: Main-power +2.5V abnormality
74: Main-power +1.8V abnormality
75: Standby-power analog +3.3V abnormality
76: Main-power analog +3.3V abnormality
77: Main-power digital +3.3V abnormality
78: Power-good signal +4.2V abnormality
80: Cooling fan-1 abnormality
81: Cooling fan-2 abnormality
82: Cooling fan-3 abnormality
90: Inverter abnormality
The byte data 70 is encoded as ASCII characters '7' and '0' (37h and 30h).
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5
Check code
for a BCC calculation.
Delimiter
CR (0Dh): End of packet
12. Serial No. & Model Name Read
12.1 Serial No. Read
This command is used in order to read a serial number.
1) The controller requests the monitor to read a serial number.
Header
Message
Check code
Delimiter
SOH-'0'-Monitor ID-'0'-'A'-'0'-'6'
STX-'C'-'2'-'1'-'6'-ETX
BCC
CR
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to get serial number.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'6'(30h, 36h): Message length
Message
STX (02h): Start of Message
'C'-'2'-'1'-'6' (43h, 32h, 31h, 36h): Serial No. command
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5
Check code
for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies the serial No. data to the controller.
Header
Message
Check code Delimiter
SOH-'0'-'0'-Monitor ID-'B'-N-N
STX-'C'-'3'-'1'-'6'-
Data(0)-Data(1)---Data(n)-ETX
BCC
CR
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.)
When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
N-N: Message length