General Parts Replacement HIGH VOLTAGE WARNING - This equipment is supplied with line voltage from a standard wall socket. Use standard precautions in working on it with line voltage applied. Failure to practice normal electrical safety precautions can cause electrical shock, personal injury or property damage. 9. Unplug the red terminal (3), brown terminal (2) and black terminal (1) wires from the selector switch by pushing a paper clip (straightened) under the wire into the switch while pulling on the wire lightly. 10. Remove the white motor wire from the power supply board line neutral connection. 11. Remove the motor and replace it with the new motor. MOTOR WIRE 12. Reverse the above steps to replace the motor. 13. It is important that the motor isolators are installed correctly and are seated as designed. Contacts on side of insulator should fit over motor bearing bracket. Motor and isolators must fit securely. ISOLATOR PAD 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

18
General Parts Replacement
HIGH VOLTAGE WARNING -
This equipment is supplied with line voltage from a
standard wall socket.
Use standard precautions in working on it with line voltage
applied.
Failure to practice normal electrical safety precautions can cause
electrical shock, personal injury or property damage.
9.
Unplug the red terminal (3), brown
terminal (2) and black terminal (1) wires
from the selector switch by pushing a
paper clip (straightened) under the wire
into the switch while pulling on the wire
lightly.
10. Remove the white motor wire from the
power supply board line neutral
connection.
11.
Remove the motor and replace it with the
new motor.
12. Reverse the above steps to replace the
motor.
13. It is important that the motor isolators are
installed correctly and are seated as
designed.
Contacts on side of insulator
should fit over motor bearing bracket.
Motor and isolators must fit securely.
MOTOR WIRE