General Parts Replacement Led Assembly Removal and Replacement 1. Follow steps 1, 2, and 6 of Motor Removal and Replacement. 2. Disconnect the two red led leads from the power supply board and remove the led assembly by removing the led retaining ring from the back of the front panel and removing the led and the leads. 3. Replace with a new led assembly. 4. Reverse the above steps 1 and 2 to replace the led assembly. Cell Assembly Removal and Replacement 1. Follow steps 1and 2 of Motor Removal and Replacement. 2. Replace with a new cell. 3. Reverse the above step 1 to replace the cell. LED LEADS Ionizer Needle Removal and Replacement 1. Follow steps 1, 3, and 6 of Motor Removal and Replacement. EXTREME HIGH VOLTAGE WARNING - This equipment is supplied with line voltage from a standard electrical wall socket. That voltage is transformed to a 24V signal that is then amplified to over 6000 VDC. In working with the equipment you must always know the voltage level for the equipment and wiring. Attempting to measure or work with the 6000 VDC power without using the proper high voltage probe can cause electrical shock, personal injury or property damage. Probing a high voltage without the proper meter will potentially damage the volt meter. 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

23
General Parts Replacement
Led Assembly Removal and Replacement
1.
Follow steps 1, 2, and 6 of
Motor Removal and Replacement
.
2.
Disconnect the two red led leads from the
power supply board and remove the led
assembly by removing the led retaining
ring from the back of the front panel and
removing the led and the leads.
3.
Replace with a new led assembly.
4.
Reverse the above steps 1 and 2 to
replace the led assembly.
Cell Assembly Removal and Replacement
1.
Follow steps 1and 2 of
Motor Removal and Replacement
.
2.
Replace with a new cell.
3.
Reverse the above step 1 to replace the
cell.
Ionizer Needle Removal and Replacement
1.
Follow steps 1, 3, and 6 of
Motor Removal and Replacement
.
EXTREME HIGH VOLTAGE WARNING -
This equipment is supplied with line
voltage from a standard electrical wall socket.
That voltage is transformed to a
24V signal that is then amplified to over 6000 VDC.
In working with the equipment
you must always know the voltage level for the equipment and wiring.
Attempting
to measure or work with the 6000 VDC power without using the proper high
voltage probe can cause electrical shock, personal injury or property damage.
Probing a high voltage without the proper meter will potentially damage the volt
meter.
LED LEADS