Panasonic BLPA300A BLPA300A User Guide - Page 11

Installation, Registration, For assistance, please call: 1-800-272-7033], MASTER, TERMINAL

Page 11 highlights

Installation Registration Installation Follow the procedure below when you want to: • Add an additional terminal to your HD-PLC network. • Re-register the master and terminal after resetting the master. 1. Confirm that the mode selector of the master adaptor is set to MASTER and the MASTER indicator is lit green. 2. Confirm that the mode selector of the terminal adaptor that you want to register is set to TERMINAL. 3. Plug the power strip into the same wall outlet that the master adaptor is plugged into. • Registration may not be successful if the master and power strip are connected to different wall outlets during registration. • Make sure the power strip is turned on. Do not use a power strip with a noise filter or surge protector feature. 4. Plug the terminal adaptor into the power strip. MASTER MASTER TERMINAL MASTER TERMINAL TERMINAL 5. Reset the terminal by pressing the FACTORY DEFAULT RESET button on the terminal for about 3 seconds (see page 18). • Check the position of the adaptor's mode selector (see page 9) and make sure that you reset the terminal adaptor (not the master). 6. Press the SETUP button on both adaptors for about 1 second. The order in which they are pressed does not matter. • The PLC indicator of each adaptor will begin to flash in green. • Make sure you press the SETUP button on each adaptor within 3 seconds of each other. [For assistance, please call: 1-800-272-7033] 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

11
[For assistance, please call: 1-800-272-7033]
Installation
Installation
Registration
Follow the procedure below when you want to:
Add an additional terminal to your
HD-PLC
network.
Re-register the master and terminal after resetting the master.
1.
Confirm that the mode selector of the master adaptor is set to
MASTER
and the
MASTER
indicator is lit green.
2.
Confirm that the mode selector of the terminal adaptor that you want to
register is set to
TERMINAL
.
3.
Plug the power strip into the same wall outlet that the master adaptor
is plugged into.
Registration may not be successful if the master and power strip
are connected to different wall outlets during registration.
Make sure the power strip is turned on. Do not use a power strip
with a noise filter or surge protector feature.
4.
Plug the terminal adaptor into the power strip.
5.
Reset the terminal by pressing the
FACTORY DEFAULT RESET
button
on the terminal for about 3 seconds (see page 18).
Check the position of the adaptor’s mode selector (see page 9)
and make sure that you reset the terminal adaptor (not the
master).
6.
Press the
SETUP
button on both adaptors for about 1 second. The
order in which they are pressed does not matter.
The
PLC
indicator of each adaptor will begin to flash in green.
Make sure you press the
SETUP
button on each adaptor within 3
seconds of each other.
MASTER
TERMINAL
MASTER
TERMINAL
MASTER
TERMINAL