Panasonic KX-TA82483 Programming Guide - Page 186
Automatic Line Access, CPC Signal Detection-Incoming
UPC - 037988851393
View all Panasonic KX-TA82483 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 186 highlights
9.3 CO [3] Default All outside (CO) lines: 600 ms Value Range 80 ms, 100 ms, 160 ms, 300 ms, 600 ms, 900 ms, 1200 ms Programming Manual References [418] Flash/Recall Time Feature Manual References 1.1.56 External Feature Access (EFA) 1.1.60 Flash/Recall Automatic Line Access Specifies which outside (CO) line is seized automatically when an extension user dials the Automatic Line Access number (9). Default All outside (CO) lines: On Value Range On (checked), Off (unchecked) Programming Manual References [419] Automatic Designated Line Access Feature Manual References 1.1.72 Line Access, Automatic 1.1.76 Line Preference-Outgoing CPC Signal Detection-Incoming Selects the length of time required by the PBX to detect a calling party control (CPC) signal from an incoming outside (CO) line call before disconnecting the line. Default All outside (CO) lines: 350 ms Value Range Disable, 22-614 ms in 8 ms increments Programming Manual References [420] CPC Signal Detection-Incoming Feature Manual References 1.1.31 Calling Party Control (CPC) Signal Detection 186 Programming Manual