Panasonic PTDS8500U PTDS8500U User Guide - Page 107
Maintenance, Monitor Lamp indicators, Managing the indicated problems
UPC - 885170010994
View all Panasonic PTDS8500U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 107 highlights
Monitor Lamp indicators Managing the indicated problems If a problem should occur with the projector, the indicators will inform you. Manage the indicated problems as follow. Attention Power indicator (STANDBY (R) / ON (G)) Lamp1 indicator (LAMP1) Lamp2 indicator (LAMP2) Temperature indicator (TEMP) Filter indicator (FILTER) JJLAMP1/LAMP2 indicator Lamp indication Information Check point Remedial measure Indicates the time Lighting in red for replacing the lamp unit. zzThis lamp monitor lights up when the zzDid you notice a "REPLACE lamp unit used hours have reached LAMP" message on the screen 2 800 hours (when [HIGH] is selected when turning on the projector as the [LAMP POWER] setting). power supply? zzRequest the dealer to replace the lamp unit. Blinking in red Lamp unit is not zzCheck the lamp unit (once) installed. compartment. zzInstall the lamp unit. zzWhen lamp unit is installed and still having the indicator lights, contact to the dealer. Blinking in red (3 times) Error is detected in the lamp circuit. zzDid you turn the power back on immediately after turning it off? zzSome error has arisen in the lamp circuit. zzCheck for fluctuation (or drop) in the source voltage. zzWait until the lamp has cooled off, and then turn on the power. zzTurn off the MAIN POWER switch using the procedure on page 40 and consult the dealer. Note zzIf no problem is found or the problem remains, do not turn on the projector. Instead contact your dealer. Maintenance ENGLISH - 107