c.Replacing needle (S) DURING THIS OPERATION DISCONNECT THE MAINS PLUG FROM THE POWER SOURCE. 1 Removing needle (s) Turn the pulley wheel towards you by hand, (in the direction of the arrow), raising the needle (s) to the highest position. Using a screwdriver, loosen the needle clamp screw and remove the needle(s). If necessary, use the tweezers supplied. 2. Fitting new needle(s) Whilst in this position, insert new needle(s) fully upwards into the needle holder(s) making sure that the long groove in the needle(s) face towards you. Then using a screwdriver, re-tighten the needle clamp screw securely. The recommended needle system are: 130 / 705H, and the normal recommended size is No.90. Depending on the weight of fabric you are using Needle sizes from No. 75 to No. 90 may be used. Light weight materials needing a finer needle, with a thicker needle for heavier weights. Ensure you carry out this procedure correctly as to not do so could result in thread or needle breakage and also skipped stitches. Fitting the left needle screw ATTENTION When replacing needles, please take note of the illustrations below: The needle clamp screw for each needle crosses the other. It is important to prop erly insert the screws when refitting needles. Take special care not to try to put back F.ftng the right needle the screw straight but rather follow the slant and do not force the screw. cramp Needle clamp screw 16