ProForm Power 595i Uk Manual - Page 27

Unplug The Power

Page 27 highlights

SYMPTOM: The walking belt is off-center SYMPTOM: The tablet holder does not stay in place The edges of the walking belt should be aligned with the belt alignment marks (see the drawing below) on the foot rails. If necessary, follow the instructions below to align the walking belt. a. Rotate the tablet holder backwards. Then, tighten the indicated screw slightly until the tablet holder stays in place when it is rotated to the desired position. a. IMPORTANT: If the walking belt rubs against the foot rails, the walking belt may become dam- a aged. First, remove the key and UNPLUG THE POWER CORD. If the walking belt has shifted to the left, use the hex key to turn the left idler roller screw clockwise 1/2 of a turn; if the walking belt has shifted to the right, turn the left idler roller screw counterclockwise 1/2 of a turn. Be careful not to overtighten the walking belt. Then, plug in the power cord, insert the key, and walk on the treadmill for a few minutes. Repeat until the walk- ing belt is centered. Screw Tablet Holder a Marks SYMPTOM: The walking belt slips when walked on a. First, remove the key and UNPLUG THE POWER CORD. Using the hex key, turn both idler roller screws clockwise, 1/4 of a turn. When the walking belt is correctly tightened, you should be able to lift each edge of the walking belt 2 to 3 in. (5 to 7 cm) off the walking platform. Be careful to keep the walking belt centered. Then, plug in the power cord, insert the key, and walk on the treadmill for a few minutes. Repeat until the walking belt is properly tightened. a 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

27
SYMPTOM: The walking belt is off-center
The edges of the walking belt should be aligned with
the belt alignment marks (see the drawing below) on
the foot rails. If necessary, follow the instructions below
to align the walking belt.
a.
IMPORTANT: If the walking belt rubs against the
foot rails, the walking belt may become dam
-
aged.
First, remove the key and
UNPLUG THE
POWER CORD.
If the walking belt has shifted to
the left,
use the hex key to turn the left idler roller
screw clockwise 1/2 of a turn;
if the walking belt
has shifted to the right,
turn the left idler roller
screw counterclockwise 1/2 of a turn. Be careful
not to overtighten the walking belt.
Then, plug in
the power cord, insert the key, and walk on the
treadmill for a few minutes. Repeat until the walk-
ing belt is centered.
SYMPTOM: The walking belt slips when walked on
a.
First, remove the key and
UNPLUG THE POWER
CORD.
Using the hex key, turn both idler roller
screws clockwise, 1/4 of a turn. When the walk-
ing belt is correctly tightened, you should be able
to lift each edge of the walking belt 2 to 3 in. (5 to
7 cm) off the walking platform. Be careful to keep
the walking belt centered. Then, plug in the power
cord, insert the key, and walk on the treadmill for a
few minutes. Repeat until the walking belt is prop-
erly tightened.
SYMPTOM: The tablet holder does not stay in place
a.
Rotate the tablet holder backwards. Then, tighten
the indicated screw slightly until the tablet holder
stays in place when it is rotated to the desired
position.
a
Tablet
Holder
Screw
a
a
Marks