Ricoh P C200W Printer Languages and Interfaces Technical Reference - Page 110

statusdict, appletalktype, Device Parameters for the Communication Device %AppSocket%, %AppSocketA

Page 110 highlights

PostScript emulation 110 Key NodeID On PCLSmartSwitch PortLocation Type integer Boolean Boolean string Definition (Read‑only). Designates if the communication channel is On and able to receive and send data. Supported values are: • True-Data is sent and processed. • False-Data is lost. Supported values are: • True-PCL SmartSwitch is set to On. • False-PCL SmartSwitch is set to Off. For more information, see "Selecting PCL emulation" on page 6. (Read‑only) Designates the physical location of the port related to the parameter set. Supported values are: • Standard Port • Option Slot 1 • Option Slot 2 • Option Slot 3 • Option Slot 4 PSSmartSwitch Boolean Supported values are: • True-PS SmartSwitch is set to On. • False-PS SmartSwitch is set to Off. For more information, see "Selecting PostScript emulation" on page 90. TokenTalkType string Setting this variable does not affect the value of other physical internal print servers. Note: The statusdict string appletalktype is correct for the current job port. Type name (Read‑only) Always returns the value of /Communications. Zone string Returns the value identified when the printer makes connection to the network at power-on. Device Parameters for the Communication Device %AppSocket%, %AppSocketA%, %AppSocketB%, %AppSocketC%, %AppSocketD% DelayedOutputClose Boolean Selects how the printer manages the port at the end of each print job. Supported values are: • True-An end‑of‑file message is not sent until the current job and all preceding jobs finish printing. • False-An end‑of‑file message is sent when a job finishes executing in the interpreter, whether the job has finished printing. Note: This value is set individually for each port.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136

PostScript emulation
110
Key
Type
Definition
NodeID
integer
(Read
only).
On
Boolean
Designates if the communication channel is On and able to receive and
send data.
Supported values are:
True—Data is sent and processed.
False—Data is lost.
PCLSmartSwitch
Boolean
Supported values are:
True—PCL SmartSwitch is set to On.
False—PCL SmartSwitch is set to Off.
For more information, see
“Selecting PCL emulation” on page 6
.
PortLocation
string
(Read
only) Designates the physical location of the port related to the
parameter set.
Supported values are:
Standard Port
Option Slot 1
Option Slot 2
Option Slot 3
Option Slot 4
PSSmartSwitch
Boolean
Supported values are:
True—PS SmartSwitch is set to On.
False—PS SmartSwitch is set to Off.
For more information, see
“Selecting PostScript emulation” on page 90
.
TokenTalkType
string
Setting this variable does not affect the value of other physical internal
print servers.
Note:
The
statusdict
string
appletalktype
is correct for the current job
port.
Type
name
(Read
only) Always returns the value of /Communications.
Zone
string
Returns the value identified when the printer makes connection to the
network at power-on.
Device Parameters for the Communication Device %AppSocket%, %AppSocketA%, %AppSocketB%,
%AppSocketC%, %AppSocketD%
DelayedOutputClose
Boolean
Selects how the printer manages the port at the end of each print job.
Supported values are:
True—An end
of
file message is not sent until the current job and all
preceding jobs finish printing.
False—An end
of
file message is sent when a job finishes executing
in the interpreter, whether the job has finished printing.
Note:
This value is set individually for each port.