Samsung DVE41A3000W User Manual - Page 15
Ducting requirements, If you integrate the dryer's vent system with an existing exhaust system, make
View all Samsung DVE41A3000W manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Installation requirements Ducting requirements Recommended Use only for short-run installation Weather hood type No. of 90° elbows 0 1 2 3 4" (10.2 cm) Rigid 80 ft. (24.4 m) 68 ft. (20.7 m) 57 ft. (17.4 m) 47 ft. (14.3 m) 2.5" (6.4 cm) Rigid 74 ft. (22.6 m) 62 ft. (18.9 m) 51 ft. (15.5 m) 41 ft. (12.5 m) NOTE * Use a 4-inch (10.2 cm) diameter rigid aluminum or galvanized steel duct. If you integrate the dryer's vent system with an existing exhaust system, make sure: • The exhaust system meets all applicable local, state, and national regulations. • Not to use a flexible plastic duct. • To regularly check and clean all lint buildup from inside the existing ducts. • The duct is not kinked or crushed. • The exhaust hood damper opens and closes freely. Manometer measurements The static pressure in any exhaust system must not exceed 0.83 inches of water column or be less than 0. Note that these values are measured with the dryer running with a manometer presented to the exhaust duct that connects to the dryer. The dryer drum must be empty and the lint filter clean. DV3000A(SEM)_DC68-03784P-00_EN.indd 15 English 15 2020-12-07 4:50:50