SMART PANEL:LSU Failure: #U2-1114. Turn off then
UPC - 635753627763
View all Samsung ML-1665 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 107 highlights
• Code:U2-1114 • Error message: SMART PANEL:LSU Failure: #U2-1114. Turn off then on. • Symptom/Cause: 1. An error between the LSU(Laser Scanning Unit) and the control circuit of the Main board has occurred. • Trouble Shooting Method: 1. Check the LSU connector. 2. Replace the LSU. 3. If the problem persists, replace the main board. ED:2010-04-08 Samsung Eletronics 22
ED:2010-04-08
Samsung Eletronics
22
• Code:U2-1114
• Error message:
SMART PANEL:LSU Failure: #U2-1114. Turn off then on.
• Symptom/Cause:
1. An error between the LSU(Laser Scanning Unit) and the control circuit of the Main board has occurred.
• Trouble Shooting Method:
1. Check the LSU connector.
2. Replace the LSU.
3. If the problem persists, replace the main board.