Samsung SCV-3080 User Manual - Page 20

Connecting to Power

Page 20 highlights

Connection Connecting to Power Connect the adaptor to the power input terminal as shown in the figure below. • Output of the adaptor should be either one of AC 24 V, 1.5 A or DC 12 V, 1.0 A. Note that using DC 12 V may cause lower heater temperature. • ---- Power Input Terminal When the resistance value of copper wire is at [20˚C(68˚F)] Copper wire size (AWG) #24(0.22mm2) #22(0.33mm2) #20(0.52mm2) Resistance (Ω/m) 0.078 0.050 0.030 Voltage Drop (V/m) 0.028 0.018 0.011 #18(0.83mm2) 0.018 0.006 • As shown in the table above, voltage decreases as the wire gets longer. Therefore use of • an excessively long adaptor output line for connection to the camera may affect the performance of the camera. * There may be some deviation in voltage drop depending on the type of wire and the manufacturer. Notes • Be sure to connect power only after all the installation is complete. • Note that AC / DC adaptor is not supplied with camera. • Ground should be connected to the GND terminal. COLOR DOME CAMERA 20 SCV-3080

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

COLOR DOME CAMERA
SCV-3080
20
Connect the adaptor to the power input terminal as shown in the figure below.
Output of the adaptor should be either one of AC 24 V, 1.5 A or DC 12 V, 1.0 A. Note that using
DC 12 V may cause lower heater temperature.
Connecting to Power
----
Power Input Terminal
As shown in the table above, voltage decreases as the wire gets longer. Therefore use of
an excessively long adaptor output line for connection to the camera may affect the
performance of the camera.
* There may be some deviation in voltage drop depending on the type of wire and the manufacturer.
When the resistance value of copper wire is at [20˚C(68˚F)]
Copper wire size (AWG)
#24(0.22mm
2
)
#22(0.33mm
2
)
#20(0.52mm
2
)
#18(0.83mm
2
)
Resistance (Ω/m)
0.078
0.050
0.030
0.018
Voltage Drop (V/m)
0.028
0.018
0.011
0.006
Connection
• Be sure to connect power only after all the installation is complete.
• Note that AC / DC adaptor is not supplied with camera.
• Ground should be connected to the GND terminal.
Notes