Page 52 highlights
Flow Chart of Troubleshooting 9-12. GSM Receiver RX ON RF input : CH center freq : +67.7kHz Amp : -50dBm Yes F100 Pin13 No >= -65dBm Resolder CN100,C104 Yes F100 Pin1,2 >= -68dBm Yes U101 pin 23 >= -70dBm pin 24 >= -70dBm No Check F100 pin9,pin10 = L Yes No Resolder C116, C119, L113 Yes No U101 pin 4,5,6,7 >= 1V U101 pin12,13,28,29 >=2.8V Yes Yes Check UCP200 No Check ANT Switch control circuit Resolder F100 No Check & Resolder U101, RF PSU Part Resolder U101 END 9-20 SAMSUNG Proprietary-Contents may change without notice This Document can not be used without Samsung's authorization
SAMSUNG Proprietary-Contents may change without notice
This Document can not be used without Samsung's authorization
Flow Chart of Troubleshooting
9-20
9-12. GSM Receiver
RX ON
RF input : CH center freq : +67.7kHz
Amp : -50dBm
Yes
F100 Pin13
>= -65dBm
No
Resolder
CN100,C104
Yes
Check ANT Switch
control circuit
F100 Pin1,2
>= -68dBm
Check F100
pin9,pin10
=L
No
No
Yes
Yes
Resolder F100
No
Resolder
C116, C119, L113
U101
pin 23
>= -70dBm
pin 24
>= -70dBm
Yes
No
U101
pin12,13,28,29
>=2.8V
U101
pin 4,5,6,7
>= 1V
No
Check & Resolder
U101,
RF PSU
Part
Yes
Yes
Resolder U101
Check
UCP200
END