Sanyo CE42LM4N-NA RS232C Basic - Page 17

See Functional Execution Command Table.

Page 17 highlights

8. Addressing Format command overview Addressing format command is used for operating multiple TV sets from one PC via RS232C control line. Addressing format command is defined one command/one line that starts with "A" and ends with carriage return (0x0D). When the TV receives carriage return (0x0D), the TV starts to decode. Address is added at the top of control command as follows. (Control command is defined as same as command without address.) [Example] Functional execution command: "A001C05" [CR] means address is "001" and control command is "C05". Status read command: "A001CR0" [CR] means address is "001" and control command is "CR0". The TV can set its own address in hotel option menu. Address can be set in the range of "001" to "999" . Default address is "001". The TV clears the information of receiving buffer and the function is not executed when the following condition occurs. 1) When it takes more than one second until the TV receives carriage return since it has received the first data "C" and /or 2) When LF (0x0A) or EOF (0x1A) is received. 8.2 Functional execution command with address 8.2.1 Format 1) PC issues a command in format as below. "A" Address "C" Command [CR] (PC ( TV) or "A" Address "CF_ " Command "_" Parameter [CR] (PC ( TV) Address: 3 digit number ( 001 to 999 ) Command / Parameter: See Functional Execution Command Table. "_" means space. 2) Only TV with which address matches responds. The TV returns "ACK" and decode or returns "?" to PC. [ACK] [CR] (0x06, 0x0D) When received command is appropriate. "?" [CR] When received command is not appropriate. [NOTE] If received address is "FFF", all TVs execute the command but never respond to PC. Ver. Page 16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19

Ver.
Page
16
8.
Addressing Format command
overview
Addressing format command is used for operating multiple TV sets from one PC via RS232C control
line.
Addressing format command is defined one command/one line that starts with “A” and ends with
carriage return (0x0D).
When the TV receives carriage return (0x0D), the TV starts to decode.
Address is added at the top of control command as follows. (Control command is defined as same as
command without address.)
[Example]
Functional execution command:
“A001C05” [CR]
means address is “001” and control command is “C05”.
Status read command:
“A001CR0” [CR]
means address is “001” and control command is “CR0”.
The TV can set its own address in hotel option menu. Address can be set in the range of “001” to
“999” .
Default address is “001”.
The TV clears the information of receiving buffer and the function is not executed when the following
condition occurs.
1) When it takes more than one second until the TV receives carriage return since it has
received the first data “C” and /or
2) When LF (0x0A) or EOF (0x1A) is received.
8.2 Functional execution command with address
8.2.1 Format
1)
PC issues a command in format as below.
“A” Address “C” Command [CR]
(PC ( TV)
or
“A” Address “CF_ ” Command “_” Parameter [CR]
(PC ( TV)
Address: 3 digit number ( 001 to 999 )
Command / Parameter:
See Functional Execution Command Table.
“_” means space.
2)
Only TV with which address matches responds. The TV returns “ACK”
and decode or returns “?” to PC.
[ACK] [CR]
(0x06, 0x0D)
When received command is appropriate.
“?” [CR]
When received command is not appropriate.
[NOTE]
If received address is “FFF”, all TVs execute the command but never respond to PC.