Sanyo MPR-1013R Instruction Manual - Page 23

Replacement of fluorescent lamp, Replacement of glow starter

Page 23 highlights

ROUTINE MAINTENANCE Replacement of fluorescent lamp 1. The fluorescent lamp is placed vertically at the center of the frame (MPR1013 and MPR-1013R) and horizontally at the top front of the cabinet (MPR-513 and MPR-513R) 2. Turn off the fluorescent lamp switch and disconnect the power supply plug . 3. For MPR-513 and MPR-513R, remove the top shelf, for MPR-1013 and MPR-1013R, remove all shelves in the left side of the cabinet. 4. As shown in Fig. 1 and Fig. 2, pull the fluorescent lamp towards the rear together with the cover and wiring. 5. Take out the fluorescent lamp and remove the connector water-proofing rubber at both ends. As shown in Fig. 3, shift the rubber by rolling it. 6. Pull out the fluorescent lamp. Pull gently from the cover. 7. After replacing a new fluorescent lamp, return it to the original position. Recommended fluorescent lamp: MPR-513, MPR-513R: FL20SD MPR-1013, MPR-1013R: FL40SD Replacement of glow starter MPR-1013 MPR-1013R Fig. 1 MPR-513 MPR-513R Fig. 2 Fig. 3 The glow starter is located on the right side of top front for MPR-513 and MPR-513R, and center of top front for MPR-1013 and MPR-1013R in the chamber. 1. Turn off the fluorescent lamp and then disconnect the power supply cord of the refrigerator. glow starter 2. Remove the water-proof cover and take out the glow starter. 3. Attach a new lamp surely. The starter designation is as follows: MPR-513, MPR-513R: FG-1P MPR-1013, MPR-1013R: FG-4P cover 4. Replace the water-proof cover on the glow starter. 22

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

22
ROUTINE MAINTENANCE
Replacement of fluorescent lamp
1.
The fluorescent lamp is placed vertically at the
center of the frame (MPR1013 and MPR-1013R) and
horizontally at the top front of the cabinet (MPR-513
and MPR-513R)
2.
Turn off the fluorescent lamp switch and disconnect
the power supply plug .
3.
For MPR-513 and MPR-513R, remove the top shelf,
for MPR-1013 and MPR-1013R, remove all shelves in
the left side of the cabinet.
4.
As shown in Fig. 1 and Fig. 2, pull the fluorescent
lamp towards the rear together with the cover and
wiring.
5.
Take out the fluorescent lamp and remove the
connector water-proofing rubber at both ends.
As
shown in Fig. 3, shift the rubber by rolling it.
6.
Pull out the fluorescent lamp.
Pull gently from the
cover.
7.
After replacing a new fluorescent lamp, return it to
the original position.
Recommended fluorescent lamp:
MPR-513, MPR-513R:
FL20SD
MPR-1013, MPR-1013R: FL40SD
Replacement of glow starter
The glow starter is located on the right side of top front for MPR-513 and MPR-513R, and center of top
front for MPR-1013 and MPR-1013R in the chamber.
1.
Turn off the fluorescent lamp and then disconnect the power
supply cord of the refrigerator.
2.
Remove the water-proof cover and take out the glow starter.
3.
Attach a new lamp surely.
The starter designation is as follows:
MPR-513, MPR-513R:
FG-1P
MPR-1013, MPR-1013R:
FG-4P
4.
Replace the water-proof cover on the glow starter.
Fig. 1
Fig. 2
Fig. 3
MPR-1013
MPR-1013R
MPR-513
MPR-513R
cover