PDG-DWL2500 Expand Serial Command Functional Specifications 9.9 Lamp Status Read Command 9.9.1 CR_LAMPREPL Command Command "CR_LAMPREPL"[CR] Details Get information of Lamp Replacement time Acceptable "000_%1"[CR] "1Y Over lamp replacement time "1N Within lamp replacement time Response %1 "1" means the number of lamps. (1 lamp model→ "1") "Y"/"N" means if it has reached its replacement time or not. e.g. "1Y projector is 1 lamp model and Lamp is over its replacement time Unacceptable "Error code"[CR] 9.9.2 CR_LAMPH Command Command "CR_LAMPH"[CR] Details Get total running time of lamp by hour (h) *Actual running time, not corresponding value Acceptable "000_%1"[CR] Response %1 "00000"~"99999" Unacceptable "Error code"[CR] 9.9.3 CR_LAMPCORRESPH Command Command "CR_LAMPCORRESPH"[CR] Details Get total running time of lamp by hour (h) * Corresponding value, not actual running time Acceptable "000_%1"[CR] Response %1 "00000"~"99999" Unacceptable Error code"[CR] 9.9.4 CR_LAMPMODE Command Command "CR_LAMPMODE"[CR] Details Get setting status of Lamp Mode Acceptable "000_%1"[CR] Response %1 "NORMAL Lamp Mode is Normal "ECO Lamp Mode is Eco Unacceptable "Error code"[CR] 59/72

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

PDG-DWL2500
Expand Serial Command Functional Specifications
59/72
9.9
Lamp Status Read Command
9.9.1
CR_LAMPREPL Command
Command
“CR_LAMPREPL”[CR]
Details
Get information of Lamp Replacement time
Acceptable
“000_%1”[CR]
%1
“1Y” -------------------------- Over lamp replacement time
“1N” -------------------------- Within lamp replacement time
“1” means the number of lamps.
(1 lamp model
“1”)
“Y”/”N” means if it has reached its replacement time or not.
e.g. “1Y” -----------projector is 1 lamp model and Lamp is over its
replacement time
Response
Unacceptable
“Error code”[CR]
9.9.2
CR_LAMPH Command
Command
“CR_LAMPH”[CR]
Details
Get total running time of lamp by hour (h)
*Actual running time, not corresponding value
Acceptable
“000_%1”[CR]
%1
“00000”~“99999”
Response
Unacceptable
“Error code”[CR]
9.9.3
CR_LAMPCORRESPH Command
Command
“CR_LAMPCORRESPH”[CR]
Details
Get total running time of lamp by hour (h)
* Corresponding value, not actual running time
Acceptable
“000_%1”[CR]
%1
“00000”~“99999”
Response
Unacceptable
Error code”[CR]
9.9.4
CR_LAMPMODE Command
Command
“CR_LAMPMODE”[CR]
Details
Get setting status of Lamp Mode
Acceptable
“000_%1”[CR]
%1
“NORMAL” -------------- Lamp Mode is Normal
“ECO” -------------------- Lamp Mode is Eco
Response
Unacceptable