Sanyo PLC-HF10000L RS232 Expand - Page 83
Lamp Status Read Commands, 9.1 CR_LAMPREPL Command, 9.2 CR_LAMPMODE Command, 9.3 CR_LAMPCONSTTAR
View all Sanyo PLC-HF10000L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 83 highlights
PLC-HF10000L Expand Serial Command Functional Specifications 9.9 Lamp Status Read Commands 9.9.1 CR_LAMPREPL Command Command "CR_LAMPREPL" [CR] Details Get the information of Lamp Replacement time Acceptable "000_%1" [CR] "2**" 2 indicates 2 lamps are used in this model. indicates the status of each lamp in lamp number order. Response %1 "Y" means the lamp operating time is over the threshold for lamp replacement, and "N" means it has not reached to. e.g. "2YN This indicates it is 2-lamp system, and Lamp #2 has not been reached to the replacement time while #1 should be replaced. Unacceptable "?" [CR] 9.9.2 CR_LAMPMODE Command Command "CR_LAMPMODE" [CR] Details Get Lamp mode setting status Acceptable "000_%1" [CR] "2LAMP Lamp mode is set to 2-Lamps "1LAMPAUTO" --- Lamp mode is set to 1-Lamp (Auto) and Response %1 automatically and preferentially uses a lamp with shorter cumulated lighting time "1LAMP1 Lamp mode is set to 1-Lamp (LAMP1) "1LAMP2 Lamp mode is set to 1-Lamp (LAMP2) "CONSTANT" ------ Lamp mode is set to Constant mode. Unacceptable "Error Code" [CR] 9.9.3 CR_LAMPCONSTTAR Command Command "CR_LAMPCONSTTAR" [CR] Details Get value of Target for Constant mode Acceptable Response %1 "000_%1" [CR] "0000"-"1024" Unacceptable "Error Code" [CR] 9.9.4 CR_LAMPCONSTCUR Command Command "CR_LAMPCONSTCUR" [CR] Details Get value of Current for Constant mode Acceptable "000_%1" [CR] Response %1 "0000"-"1024" Unacceptable "Error Code" [CR] 83/105