Sanyo PLC-HP7000L RS232C Basic - Page 15
INPUT 2 Y,Pb/Cb,Pr/Cr Command, INPUT 2 RGB Command, 24 IMAGE Command, Direct on SET Command, Direct
View all Sanyo PLC-HP7000L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
PLC-HP7000L Basic Serial Command Functional Specifications 6.22 INPUT 2 Y,Pb/Cb,Pr/Cr Command Command "C24" [CR] Detail Select Y,Pb/Cb,Pr/Cr input in Input 2. Although projector returns "OK", Input search is not executed with this command while Input button is set to Mode2 or Mode3. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.23 INPUT 2 RGB Command Command "C25" [CR] Detail Select RGB input in Input 2. Although projector returns "OK", Input search is not executed with this command while Input button is set to Mode2 or Mode3. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.24 IMAGE Command Command "C27" [CR] Detail Switch Image Setting status Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.25 Direct on SET Command Command "C28" [CR] Detail Enable Direct on This status is stored in EEPROM and retained regardless of Power OFF/ON operation. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.26 Direct on CANCEL Command Command "C29" [CR] Detail Disable Direct on This status is stored in EEPROM and retained regardless of Power OFF/ON operation. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.27 POWER MANAGEMENT READY1 Command Command "C2A" [CR] Detail Set Power Management function to ready1 status This status is stored in EEPROM and retained regardless of Power OFF/ON operation. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 15/27