PLC-HP7000L Basic Serial Command Functional Specifications 7.4 Status Read Command Command "CR0" [CR] Detail Get the projector's operating status Acceptable "%1" [CR] "00" = Power ON "80" = Standby "40" = Countdown in process "20" = Cooling Down in process "10" = Power Failure "28" = Cooling Down in process due to Abnormal Temperature Response %1 "88" = Standby after Cooling Down due to Abnormal Temperature "24" = Power-Save Cooling Down in process "04" = Power Save "21" = Cooling Down in process after OFF due to Lamp Failure "81" = Standby after Cooling Down due to Lamp Failure "2C"= Cooling Down in process after OFF due to Shutter Management "8C" = Standby after Cooling Down due to Shutter Management Unacceptable "?" [CR] 【Details for Response】 ・ "00" [CR] Status: Power ON Normal image is on-screen. ・ "80" [CR] Status: Standby When the status is Standby, Status Read Commands are always accepted, but any Functional Execution Commands are not accepted except for POWER ON command. ・ "40" [CR] Status: Countdown in process When "Display" in Setting Menu is set to ON, Countdown operation is started by execution of POWER ON; while "Display" in Setting Menu is set to OFF, the status moves directly to Power ON without Countdown operation. When "Display" in Setting Menu is OFF, processing Countdown is not executed and the status quickly moves to Power ON. ・ "20" [CR] Status: Cooling Down in process When the status is Power ON, and then POWER OFF Command ("C01" [CR]) is executed, it moves to Cooling Down status. When lamp turns off and about 90 seconds of fan spinning finishes, the above status automatically moves to Standby (The fan spinning time depends on models.) This function is intended to cool down lamps and other optical parts, and is quite important for projector's reliability. During this time, any Functional Execution Command is invalid. 23/27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27

PLC-HP7000L Basic Serial Command Functional Specifications
23/27
7.4 Status Read Command
Command
“CR0” [CR]
Detail
Get the projector’s operating status
Acceptable
“%1” [CR]
%1
”00” = Power ON
“80” = Standby
“40” = Countdown in process
“20” = Cooling Down in process
“10” = Power Failure
“28” = Cooling Down in process due to Abnormal Temperature
“88” = Standby after Cooling Down due to Abnormal Temperature
“24” = Power-Save Cooling Down in process
“04” = Power Save
“21” = Cooling Down in process after OFF due to Lamp Failure
“81” = Standby after Cooling Down due to Lamp Failure
“2C”= Cooling Down in process after OFF due to
Shutter Management
“8C” = Standby after Cooling Down due to Shutter Management
Response
Unacceptable
“?” [CR]
Details for Response
“00” [CR]
Status: Power ON
Normal image is on-screen.
“80” [CR]
Status: Standby
When the status is Standby, Status Read Commands are always accepted, but any
Functional Execution Commands are not accepted except for POWER ON command.
“40” [CR]
Status: Countdown in process
When “Display” in Setting Menu is set to ON, Countdown operation is started by execution
of POWER ON; while “Display” in Setting Menu is set to OFF, the status moves directly to
Power ON without Countdown operation. When “Display” in Setting Menu is OFF,
processing Countdown is not executed and the status quickly moves to Power ON.
“20” [CR]
Status: Cooling Down in process
When the status is Power ON, and then POWER OFF Command (“C01” [CR]) is executed,
it moves to Cooling Down status.
When lamp turns off and about 90 seconds of fan spinning finishes, the above status
automatically moves to Standby (The fan spinning time depends on models.)
This function is intended to cool down lamps and other optical parts, and is quite important
for projector’s reliability. During this time, any Functional Execution Command is invalid.