Troubleshooting Condition/Problem No display/partial display/ unit will not turn on Things to Check Check electrical (wall) outlet Check connection at front (recumbent) or rear (upright) of unit Check data cable integrity Check data cable connections/orientation Check console display for damage Console Display Unit operates but Contact HR not displayed HR cable connection at Console HR cable box connection (recumbent only) Sensor grip Dry or calloused hands Handlebars Console displays "E2" error Check data cable integrity code Check data cable connections/orientation Console Electronics No speed/RPM reading, Check data cable integrity Console displays "E3" error code Check data cable connections/orientation Check magnet position (requires shroud removal) Check RPM Sensor (requires shroud removal) Console shuts off (enters Check data cable integrity sleep mode) while in use Solution Make sure unit is plugged into a functioning wall outlet. Connection should be secure and undamaged. Replace adapter or connection at unit if either are damaged. All wires in cable should be intact. If any are visibly crimped or cut, replace cable. Be sure cable is connected securely and oriented properly. Small latch on connector should line up and snap into place. Check for visual sign that console display is cracked or otherwise damaged. Replace Console if damaged. If Console only has partial display and all connections are fine, replace the Console. If the above steps do not resolve the problem, contact Customer Care for further assistance. Be sure cable is connected securely to Console. Be sure cables from handlebars and cable to Console are secure and undamaged. Some models may require the seat back be raised to access cable box. Be sure hands are centered on HR sensors. Hands must be kept still with relatively equal pressure applied to each side. Sensors may have difficulty with dried out or calloused hands. A conductive electrode cream such as "Signa Crème" or "BuhBump" can help make better conduct. These are available on the web or at medical or some larger fitness stores. If tests reveal no other issues, Handlebars should be replaced. All wires in cable should be intact. If any are cut or crimped, replace cable. Be sure cable is connected securely and oriented properly. Small latch on connector should line up and snap into place. If tests reveal no other issues, Console should be replaced. All wires in cable should be intact. If any are cut or crimped, replace cable. Be sure cable is connected securely and oriented properly. Small latch on connector should line up and snap into place. Magnet should be in place on pulley. RPM sensor should be aligned with magnet and connected to data cable. Realign sensor if necessary. Replace if there is any damage to the sensor or the connecting wire. All wires in the cable should be intact. If any are cut or crimped, replace cable. 32

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

32
TROUBLESHOOTING
Condition/Problem
Things to Check
Solution
No display/partial display/
unit will not turn on
Check electrical (wall)
outlet
Make sure unit is plugged into a functioning wall outlet.
Check connection at front
(recumbent) or rear (up-
right) of unit
Connection should be secure and undamaged. Replace adapter
or connection at unit if either are damaged.
Check data cable integrity
All wires in cable should be intact. If any are visibly crimped or
cut, replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly. Small
latch on connector should line up and snap into place.
Check console display for
damage
Check for visual sign that console display is cracked or otherwise
damaged. Replace Console if damaged.
Console Display
If Console only has partial display and all connections are fine,
replace the Console.
If the above steps do not resolve the problem, contact Customer
Care for further assistance.
Unit operates but Contact
HR not displayed
HR cable connection at
Console
Be sure cable is connected securely to Console.
HR cable box connection
(recumbent only)
Be sure cables from handlebars and cable to Console are secure
and undamaged. Some models may require the seat back be
raised to access cable box.
Sensor grip
Be sure hands are centered on HR sensors. Hands must be kept
still with relatively equal pressure applied to each side.
Dry or calloused hands
Sensors may have difficulty with dried out or calloused hands.
A conductive electrode cream such as “Signa Crème” or “Buh-
Bump” can help make better conduct. These are available on the
web or at medical or some larger fitness stores.
Handlebars
If tests reveal no other issues, Handlebars should be replaced.
Console displays “E2” error
code
Check data cable integrity
All wires in cable should be intact. If any are cut or crimped,
replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly. Small
latch on connector should line up and snap into place.
Console Electronics
If tests reveal no other issues, Console should be replaced.
No speed/RPM reading,
Console displays “E3” error
code
Check data cable integrity
All wires in cable should be intact. If any are cut or crimped,
replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly. Small
latch on connector should line up and snap into place.
Check magnet position
(requires shroud removal)
Magnet should be in place on pulley.
Check RPM Sensor (re-
quires shroud removal)
RPM sensor should be aligned with magnet and connected to
data cable. Realign sensor if necessary. Replace if there is any
damage to the sensor or the connecting wire.
Console shuts off (enters
sleep mode) while in use
Check data cable integrity
All wires in the cable should be intact. If any are cut or crimped,
replace cable.