Schwinn 430i Elliptical Assembly and Owner's Manual - Page 41

Check Speed Sensor re

Page 41 highlights

Console shuts off (enters Check electrical (wall) sleep mode) while in use outlet Make sure unit is plugged into a functioning wall outlet. Check connection at front Connection should be secure and undamaged. Replace adapter of unit or connection at unit if either are damaged. Check data cable integrity All wires in the cable should be intact. If any are cut or crimped, replace cable. Check data cable connections/orientation Be sure cable is connected securely and oriented properly. Small latch on connector should line up and snap into place. Reset machine Unplug unit from electrical outlet for 3 minutes. Reconnect to outlet. Check magnet position Magnet should be in place on pulley. (requires shroud removal) Check Speed Sensor (requires shroud removal) Speed sensor should be aligned with magnet and connected to data cable. Realign sensor if necessary. Replace if there is any damage to the sensor or the connecting wire. Fan will not turn on or will Check data cable integrity All wires in cable should be intact. If any are cut or crimped, not turn off replace cable. Check data cable connections/orientation Be sure cable is connected securely and oriented properly. Small latch on connector should line up and snap into place. Reset machine Unplug unit from electrical outlet for 3 minutes. Reconnect to outlet. Fan will not turn on, but Console operates Check for blockage of fan Unplug unit from electrical outlet for 5 minutes. Remove material from fan. If necessary, detach the Console to help with removal. Replace the Console if unable to remove blockage. Unit rocks/does not sit level Check leveler adjustment Adjust levelers until machine is level. Check surface under unit Adjustment may not be able to compensate for extremely uneven surfaces. Move machine to level area. Foot pedals loose/unit dif- Hardware ficult to operate Tightly secure all hardware on the Pedal Arms and Handlebar Arms. Drive train click/tick noise once per full crank revolution Check crank/pulley assembly Disconnect left and right foot assemblies and rotate crank. If sound persists, replace crank/pulley assembly. If sound does not come from rotating crank, check foot assemblies and upper/ lower handlebars. Check foot assemblies, leg Manually move foot, leg, and handlebar assemblies to isolate assemblies, handlebar sound. Replace part making sound. assemblies Squeaking noise that appears a few minutes into a workout and normally will get progressively worse as the workout continues Bolt that connects the swing arms to the axle running through the console mast Loosen pivot rod bolt slightly until noise goes away. White lithium grease can also be applied for a temporary fix. Contact your local distributor for further assistance. 41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

41
Console shuts off (enters
sleep mode) while in use
Check electrical (wall)
outlet
Make sure unit is plugged into a functioning wall outlet.
Check connection at front
of unit
Connection should be secure and undamaged. Replace adapter
or connection at unit if either are damaged.
Check data cable integrity
All wires in the cable should be intact. If any are cut or crimped,
replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly. Small
latch on connector should line up and snap into place.
Reset machine
Unplug unit from electrical outlet for 3 minutes. Reconnect to
outlet.
Check magnet position
(requires shroud removal)
Magnet should be in place on pulley.
Check Speed Sensor (re
-
quires shroud removal)
Speed sensor should be aligned with magnet and connected to
data cable. Realign sensor if necessary. Replace if there is any
damage to the sensor or the connecting wire.
Fan will not turn on or will
not turn off
Check data cable integrity
All wires in cable should be intact. If any are cut or crimped,
replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly. Small
latch on connector should line up and snap into place.
Reset machine
Unplug unit from electrical outlet for 3 minutes. Reconnect to
outlet.
Fan will not turn on, but
Console operates
Check for blockage of fan
Unplug unit from electrical outlet for 5 minutes. Remove material
from fan. If necessary, detach the Console to help with removal.
Replace the Console if unable to remove blockage.
Unit rocks/does not sit
level
Check leveler adjustment
Adjust levelers until machine is level.
Check surface under unit
Adjustment may not be able to compensate for extremely uneven
surfaces. Move machine to level area.
Foot pedals loose/unit dif
-
ficult to operate
Hardware
Tightly secure all hardware on the Pedal Arms and Handlebar
Arms.
Drive train click/tick noise
once per full crank revolu
-
tion
Check crank/pulley as
-
sembly
Disconnect left and right foot assemblies and rotate crank. If
sound persists, replace crank/pulley assembly. If sound does
not come from rotating crank, check foot assemblies and upper/
lower handlebars.
Check foot assemblies, leg
assemblies, handlebar
assemblies
Manually move foot, leg, and handlebar assemblies to isolate
sound. Replace part making sound.
Squeaking noise that ap
-
pears a few minutes into
a workout and normally will
get progressively worse as
the workout continues
Bolt that connects the
swing arms to the axle run
-
ning through the console
mast
Loosen pivot rod bolt slightly until noise goes away. White lithium
grease can also be applied for a temporary fix. Contact your local
distributor for further assistance.