Seagate ST340014AS Product Manual - Page 17

drives will spin up only after power is applied to the drive and after successful PHY Physical layer - hard drive

Page 17 highlights

2.8.1.1 Typical current profiles 1.50 1.25 1.00 Amps 0.75 0.50 0.25 0.0 +5 Volt Current during spindle start - Typical Amperes 0.0 2 4 6 8 10 12 14 16 18 Seconds Figure 1. Typical 5V startup and operation current profile 2.4 2.0 1.6 Amps 1.2 0.8 0.4 0.0 +12 Volt Current during spindle start - Typical Amperes 0.0 2 4 6 8 10 12 14 16 18 Seconds Figure 2. Typical 12V startup and operation current profile 2.8.2 Deferred spinup Barracuda 7200.7 Serial ATA drives provide a deferred spinup feature which storage subsystem controllers can use to sequence disc drive initialization. This is beneficial to systems which include multiple Serial ATA hard disc drives because it allows subsystem controllers to stagger the spinup of each drive to accommodate available power supply current. This feature does not impact time-to-ready in typical desktop systems. To accommodate the deferred spinup of multiple disc drives in an enclosure, Barracuda 7200.7 Serial ATA disc drives will spin up only after power is applied to the drive and after successful PHY (Physical layer) initialization. PHY initialization occurs after the PHY enters the DP7:DR_Ready state. This state is reached after a suc- Barracuda 7200.7 Serial ATA Product Manual, Rev. N 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

Barracuda 7200.7 Serial ATA Product Manual, Rev. N
9
2.8.1.1
Typical current profiles
Figure 1. Typical 5V startup and operation current profile
Figure 2. Typical 12V startup and operation current profile
2.8.2
Deferred spinup
Barracuda 7200.7 Serial ATA drives provide a deferred spinup feature which storage subsystem controllers
can use to sequence disc drive initialization. This is beneficial to systems which include multiple Serial ATA
hard disc drives because it allows subsystem controllers to stagger the spinup of each drive to accommodate
available power supply current. This feature does not impact time-to-ready in typical desktop systems.
To accommodate the deferred spinup of multiple disc drives in an enclosure, Barracuda 7200.7 Serial ATA disc
drives will spin up only after power is applied to the drive and after successful PHY (Physical layer) initializa-
tion. PHY initialization occurs after the PHY enters the DP7:DR_Ready state. This state is reached after a suc-
0.0
2
4
6
8
10
12
14
16
0.0
0.25
0.50
0.75
1.00
1.25
Amps
Seconds
1.50
18
+5 Volt Current during spindle start — Typical Amperes
0.0
2
4
6
8
10
12
14
16
0.0
0.4
0.8
1.2
1.6
2.0
Amps
Seconds
+12 Volt Current during spindle start — Typical Amperes
2.4
18