Seagate ST98823A Momentus 5400.2 PATA Product Manual - Page 10
Table 1, Specifications - momentus
UPC - 000062907828
View all Seagate ST98823A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
Table 1: Specifications Drive specification Read/write power (typical) Idle mode (typical) Standby mode Sleep mode Voltage tolerance (including noise) Ambient temperature Temperature gradient (°C per hour max, noncondensing) Relative humidity (noncondensing) Relative humidity gradient Wet bulb temperature (°C max) Altitude, operating Altitude, nonoperating (below mean sea level, max) Shock, operating (Gs max at 2 msec) Shock, nonoperating (Gs max at 2 msec) Shock, nonoperating (Gs max at 1 msec) Shock, nonoperating (Gs max at 0.5 msec) Vibration, operating (max displacement may apply below 10 hz) Vibration, nonoperating (max displacement may apply below 22 hz) Drive acoustics, sound power (bels) Idle* Quiet seek Performance seek Nonrecoverable read errors Mean Time Before Failure (MTBF) Load/Unload (U/UL) cycles ST9100823A ST9808211A ST960822A ST9408114A ST9308110A 2.05/2.1 watts 0.99 watts 0.2 watts (typical)** 0.2 watts (typical)** 5V ± 5% 5° to 55°C (operating) -40° to 70°C (nonoperating) 20°C (operating) 30°C (nonoperating) 5% to 90% (operating) 5% to 95% (nonoperating) 30% per hour max 30°C (operating) 40°C (nonoperating) -304.8 m to 3,048 m (-1000 ft to 10,000 ft) -304.8 m to 12,192 m (-1,000 ft to 40,000 ft) 250 800 900 400 1.0 Gs (0 to peak, 5-500 Hz) 5.0 Gs (0 to peak, 10-500 Hz) 2.4 (typical) 2.6 (max) 2.6 (typical) 2.8 (max) 2.9 (typical) 3.1 (max) 1 per 1014 bits read 330,000 power-on hours At nominal power, 25°C ambient temperature. Max case temperature: 65°C at the case measurement location shown in Figure 4. 25°C, 50% relative humidity 32°C, 80% relative humidity 5°C, 80% relative humidity 5°C, 10% relative humidity 55°C, 16% relative humidity Service life Warranty 600,000 software-controlled power on/off cycles 20,000 hard power on/off cycles 600,000 software-controlled power on/off cycles 20,000 hard power on/off cycles 5 Years 5 Years *During periods of drive idle, some offline activity may occur, according to the S.M.A.R.T. specification, which may increase acoustic and power to operational levels. **Typical notebooks will pull power to the drive when entering S3 and S4; while in the S3 and S4 states, drive sleep and drive standby modes will not contribute to battery power consumption. 4 Momentus 5400.2 Product Manual, Rev. D