2.11 Acoustics Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All measurements are consistent with ISO document 7779. Sound power measurements are taken under essentially free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward. Note. For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is defined by the following equation: (Number of seeks per second = 0.4 / (average latency + average access time) Table 4: Drive level acoustics Acoustic mode Idle* 2.4 bels (typ) 2.6 bels (max) Quiet Seek 2.6 bels (typ) 2.8 bels (max) Performance Seek 2.9 bels (typ) 3.1 bels (max) *During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power to operational levels. 2.12 Electromagnetic immunity When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the rradio frequency (RF) environments defined in the following table: Table 5: Electromagnetic immunity Test Description Performance level Electrostatic discharge Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV B Radiated RF immunity 80 to 2,000 MHz, 10 V/m, A 80% AM with 1 kHz sine 900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz Electrical fast transient ± 1 kV on AC mains, ± 0.5 kV on external I/O B Surge immunity ± 1 kV differential, ± 2 kV common, AC mains B Conducted RF immunity 150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz A sine Power Frequency H-field 1 A/m, 50Hz/60Hz, 3 axes A immunity Voltage dips, interrupts 30% Reduction for 25 cycles C >95% Reduction for 250 cycles C >95%, 0.5 cycles B Reference standard EN 61000-4-2: 95 EN 61000-4-3: 96 ENV 50204: 95 EN 61000-4-4: 95 EN 61000-4-5: 95 EN 61000-4-6: 97 EN 61000-4-8: 97 EN 61000-4-11: 94 A - 1) No upset or degradation in performance beyond manufacturer's specified limits. 2) No data loss. B - 1) Unit self recovers without user intervention. 2) No data loss. C - 1) Upset OK provided that unit will function after user intervention. Momentus 5400.2 Product Manual, Rev. D 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

Momentus 5400.2 Product Manual, Rev. D
13
2.11
Acoustics
Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All mea-
surements are consistent with ISO document 7779. Sound power measurements are taken under essentially
free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward.
Note.
For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is
defined by the following equation:
(Number of seeks per second = 0.4 / (average latency + average access time)
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and
power to operational levels
.
2.12
Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the rradio frequency (RF) environments defined in the following table:
A - 1) No upset or degradation in performance beyond manufacturer’s specified limits.
2) No data loss.
B - 1) Unit self recovers without user intervention.
2) No data loss.
C - 1) Upset OK provided that unit will function after user intervention.
Table 4:
Drive level acoustics
Acoustic mode
Idle*
Quiet Seek
Performance Seek
2.4 bels (typ)
2.6 bels (max)
2.6 bels (typ)
2.8 bels (max)
2.9 bels (typ)
3.1 bels (max)
Table 5:
Electromagnetic immunity
Test
Description
Performance
level
Reference
standard
Electrostatic discharge
Contact, HCP, VCP: ± 4
kV; Air:
± 8 kV
B
EN 61000-4-2: 95
Radiated RF immunity
80 to 2,000 MHz, 10 V/m,
80% AM with 1 kHz sine
900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz
A
EN 61000-4-3: 96
ENV 50204: 95
Electrical fast transient
± 1 kV on AC mains, ± 0.5 kV on external I/O
B
EN 61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV common, AC mains
B
EN 61000-4-5: 95
Conducted RF immunity
150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz
sine
A
EN 61000-4-6: 97
Power Frequency H-field
immunity
1 A/m, 50Hz/60Hz, 3 axes
A
EN 61000-4-8: 97
Voltage dips, interrupts
30% Reduction for 25 cycles
>95% Reduction for 250 cycles
>95%, 0.5 cycles
C
C
B