Seagate ST98823A Momentus 5400.2 PATA Product Manual - Page 17

Environmental specifications

Page 17 highlights

2.10 Environmental specifications 2.10.1 Ambient temperature Ambient temperature is defined as the temperature of the environment immediately surrounding the drive. Actual drive case temperature should not exceed 65°C (149°F) within the operating ambient conditions. Above 1,000 feet (305 meters), the maximum temperature is derated linearly by 1°C every 1000 feet. Operating 5° to 55°C (41° to 131°F) Nonoperating -40° to 70°C (-40° to 158°F) 2.10.2 Temperature gradient Operating 20°C per hour (68°F per hour max), without condensation Nonoperating 30°C per hour (86°F per hour max) 2.10.3 Humidity 2.10.3.1 Relative humidity Operating 5% to 90% noncondensing (30% per hour max) Nonoperating 5% to 95% noncondensing (30% per hour max) 2.10.3.2 Wet bulb temperature Operating 30°C (86°F max) Nonoperating 40°C (104°F max) 2.10.4 Altitude Operating -304.8 m to 3,048 m (-1,000 ft to 10,000 ft) Nonoperating -304.8 m to 12,192 m (-1,000 ft to 40,000 ft) Momentus 5400.2 Product Manual, Rev. D 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

Momentus 5400.2 Product Manual, Rev. D
11
2.10
Environmental specifications
2.10.1
Ambient temperature
Ambient temperature is defined as the temperature of the environment immediately surrounding the drive.
Actual drive case temperature should not exceed
65°C (149°F) within the operating ambient conditions.
Above 1,000 feet (305 meters), the maximum temperature is derated linearly by 1°C every 1000 feet.
2.10.2
Temperature gradient
2.10.3
Humidity
2.10.3.1
Relative humidity
2.10.3.2
Wet bulb temperature
2.10.4
Altitude
Operating
5° to 55°C (41° to 131°F)
Nonoperating
–40° to 70°C (–40° to 158°F)
Operating
20°C per hour (68°F per hour max), without condensation
Nonoperating
30°C per hour (86°F per hour max)
Operating
5% to 90% noncondensing (30% per hour max)
Nonoperating
5% to 95% noncondensing (30% per hour max)
Operating
30°C (86°F max)
Nonoperating
40°C (104°F max)
Operating
–304.8 m to 3,048 m (–1,000 ft to 10,000 ft)
Nonoperating
–304.8 m to 12,192 m (–1,000 ft to 40,000 ft)