A 8 7 6 5 4 3 2 1 A H-39 B C D E F G OPERATION/REMOCON SCHEMATIC DIAGRAM OS2201 ROM-V338TAO Vout 1 GND 2 B+ 3 R2201 330 C2205_1 6.3V 100 KA R G SH CH DOWN SW2204_3 EVQ21505R SH CH UP SW2203_3 EVQ21505R (REMOCON PCB) R2208 47 1/4W STANDBY/POWER D2201 LTL-1BEFJ-002A FROM/TO JACK2 CP2201 (CP4201) A2001WR2-5P REMOCON IN 1 GND 2 AT+5V 3 STANDBY LED 4 POWER ON LED 5 OS 26 CD2201 E8253101 (OPERATION PCB) R2207_2 330 SH INPUT SW2202_3 EVQ21505R SH VOL DOWN SW2206_3 EVQ21505R R2203_2 1.2K R2202_2 2.2K R2212 5.6K R2206_2 1.5K PCBDA0 CEG359 TO MICON CP2203_1 (CP6202) A2001WR2-3P KEY_A 3 KEY_B 2 GND 1 OS 32 CD2202_1 E8232701 PCB270 CEG358 SH VOL UP SW2205_3 EVQ21505R SH POWER SW2201_3 R2213 EVQ21505R 10 R2214 10 NOTE:THIS SCHEMATIC DIAGRAM IS THE LATEST AT THE TIME OF PRINTING AND SUBJECT TO CHANGE WITHOUT NOTICE B C D NOTE:THE DC VOLTAGE AT EACH PART WAS MEASURED WITH THE DIGITAL TESTER WHEN THE COLOR BROADCAST WAS RECEIVED IN GOOD CONDITION AND PICTURE IS NORMAL. E F G H 8 7 6 5 4 3 2 1 H H-40