LC-42D43U 2. Adjustment sequence (adjustment according to the G adjustment value of gradation 6) * Make sure the adjusting point gradations are correct since they are different for each model. Repeat until RGB become the target values. PC Set Set the light level to MAX with the light control command (SBSL0016 for 45). SBSL0016 Setting is complete. OK Multi point adjustment mode setting MSET0001 Multi point adjustment mode is set. OK Initialize adjustment values. MSET0004 Initialization is done. OK Adjustment gradation setting (point 6 = 230 gradation adjustment*) LEV60230 (WBI60920 Pattern display Adjustment values are set. OK Adjust RGB to the target xy values. MG6RXXXX MG6GXXXX MG6BXXXX * XXXX indicates the adjusted values between 0000 and 1023 (4 digit decimal number with zero fill). * In order to adjust by reducing the value, set the strongest color as the fixed color. * The default adjustment value of RGB is the parameter value of the WBI6 command multiplied by 2. The adjustment value is reflected in the image. Adjustment values are set. OK Adjustment gradation setting (point 5 = 215 gradation adjustment*) LEV50215 (WBI50860) Pattern display Adjustment values are set. OK Correction of G value MG5GXXXX When G is changed at gradation 6, calculate the ratio of the change and set the following value to XXXX: (the value set with WBI5) x 2 x (the ratio). Adjustment values are set. OK 3 - 3