Sharp R-CD2200M R-CD1200M , R-CD1800 , R-CD-2200M Operation Manual - Page 16

NOTES, Air Intake Filter Counter, Procedure, To Reset the Counter to 0, To Reset the Air Intake

Page 16 highlights

To Reset the Counter to "0" Each counter can be manually reset to "0" by pressing the START pad after the count is displayed. * Suppose you want to reset the count for memory number 1 in any Memory Input Method Procedure CUSTOM HELP x 2 7 1 Press the CUSTOM HELP pad twice within 2 seconds, then enter 7 . Total usage will be displayed. After about 1 sec. CHECK 2 Enter memory number 1 to 0 check the total memory usage of memory 1. 1 NO. CHECK NO. CHECK After about 1 sec. CHECK START 3 Press the START pad. CHECK STOP CLEAR 4 Press the STOP/CLEAR pad to exit from the Custom Help Function. NOTES: 1. Only Dual Digit Input method can be used when inputting memory numbers in Counter Check/Clear. 2. To clear total manual cooking usage, press the SELECT TIME pad in Step 2 instead of the number pad. 3. To clear total Express Defrost usage, press the EXPRESS DEFROST pad in Step 2 instead of the number pad. 4. To clear total usage, skip Step 2. 8. Air Intake Filter Counter Use Custom Help Function for Air Intake Filter Counter to check total usage hours since the Air Intake Filter was last reset to "0". CH81 : The total used air intake filter time appears. CH82 : The limit time for using a filter can be changed. Use Custom Help Function for Air Intake Filter Counter to change the Air Intake Filter cycle from 001-999. The factory setting is 100 hours. When 100 hours is exceeded, the FILTER indicator on the display will start to flash on and off as a reminder to clean the air filter, even if in the middle of cooking. Furthermore "FILt" flashes on and off in stead of displaying " . " during standby and at the same time FILTER indicator flashes on and off. Clean Air Intake Filter (See page EN-23 - EN-24), when the FILTER indicator appears in the display, and then clear the total usage to reset it to "0" . * Suppose you want to know the total usage hours which has been 99 hours since the last reset. Procedure Display 8 1 CUSTOM HELP x 2 1 Press the CUSTOM HELP pad twice within 2 seconds and enter 8, 1. After about 1 sec. CHECK STOP CLEAR 2 Press the STOP/CLEAR pad to exit from the Custom Help Function. To Reset the Air Intake Filter Counter Reset the Air Intake Filter Counter after cleaning the air intake filter. * Suppose you want to reset the air filter counter which has been 101 hours since the last reset and the Air Intake Filter cycle is preset to 100. Procedure Display 8 1 CUSTOM HELP x 2 1 Press the CUSTOM HELP pad twice within 2 seconds and enter 8,1. After about 1 sec. CHECK FILTER START 2 Press the START pad to reset the counter to "0". STOP CLEAR 3 Press the STOP/CLEAR pad to exit from the Custom Help Function. EN-15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

EN-15
NOTES:
1. Only Dual Digit Input method can be used when
inputting memory numbers in Counter Check/Clear.
2. To clear total manual cooking usage, press the SELECT
TIME pad in Step 2 instead of the number pad.
3. To clear total Express Defrost usage, press the
EXPRESS DEFROST pad in Step 2 instead of the
number pad.
4. To clear total usage, skip Step 2.
8. Air Intake Filter Counter
Use Custom Help Function for Air Intake Filter Counter
to check total usage hours since the Air Intake Filter was
last reset to “0”.
CH81 : The total used air intake filter time
appears.
CH82 : The limit time for using a filter can be
changed.
After about 1 sec.
NO.
CHECK
NO.
CHECK
1 Press the CUSTOM
HELP pad twice within 2
seconds, then enter 7 .
Total usage will be
displayed.
Procedure
x 2
CUSTOM
HELP
2 Enter memory
number 1 to
check the total
memory usage of
memory 1.
START
3 Press the START pad.
CHECK
0
7
1
CHECK
CHECK
After about 1 sec.
STOP
CLEAR
4
Press the STOP/CLEAR pad
to exit from the Custom Help
Function.
To Reset the Counter to “0”
Each counter can be manually reset to “0” by pressing
the START pad after the count is displayed.
* Suppose you want
to reset the count for memory
number 1 in any Memory Input Method
Use Custom Help Function for Air Intake Filter Counter
to change the Air Intake Filter cycle from 001-999. The
factory setting is 100 hours. When 100 hours is exceeded,
the FILTER indicator on the display will start to flash on
and off as a reminder to clean the air filter, even if in the
middle of cooking. Furthermore “FILt“
flashes on and
off
in stead of displaying “ . “ during standby and at the
same time FILTER indicator flashes on and off.
Clean Air
Intake Filter (See page EN-23 - EN-24), when the FILTER
indicator appears in the display, and then clear the total
usage to reset it to “0” .
* Suppose you want to know the total usage hours
which has been 99 hours since the last reset.
To Reset the Air Intake Filter Counter
Reset the Air Intake Filter Counter after cleaning the air
intake filter.
*
Suppose you want to reset the air filter counter which
has been 101 hours since the last reset and the Air
Intake Filter cycle is preset to 100.
1
Press the CUSTOM HELP
pad twice within
2 seconds and enter 8, 1.
Procedure
Display
CUSTOM
HELP
x2
8
1
After about 1 sec.
CHECK
Procedure
Display
1 Press the CUSTOM HELP
pad twice within
2 seconds and enter 8,1.
2 Press the START pad to
reset the counter to “0”.
x2
8
1
CUSTOM
HELP
CHECK
START
STOP
CLEAR
2 Press the STOP/CLEAR pad to exit from the
Custom Help Function.
STOP
CLEAR
3 Press the STOP/CLEAR pad to exit from
the Custom Help Function.
FILTER
After about 1 sec.