Sharp R-CD2200M R-CD1200M , R-CD1800 , R-CD-2200M Operation Manual - Page 18

NOTES, Express Defrost Setting, Pause Timing, Procedure, Display

Page 18 highlights

NOTES: 1. Only Dual Digit Input method can be used when inputting memory numbers in Multiplication Factor for Double/Triple Quantity. 2. The multiplication factors can be set from 0.01 to 9.99 for double quantity and triple quantity. 3. When you want to know the multiplication factor for triple quantity, press the DOUBLE/TRIPLE QUANTITY twice at step 1 after pressing the CUSTOM HELP pad twice. 4. Multiplication Factors for Double/Triple Quantity can be checked or changed before pressing the STOP/ CLEAR pad to exit for Custom Help Function. 11. Express Defrost Setting Express Defrosting uses 3 stages to defrost foods quickly. The defrosting sequence is preset as follows, but you can change the setting. Defrosting Time STAGE T x A1: (0.20*) + B1: (20*) 1 sec. STAGE T x A2: (0.13*) + B2: (30*) 2 sec. STAGE T - STAGE1 - STAGE2 3 Pause See the table for The Pause Timing Timing below (50*) Power Level PL1 (40*) % PL2 (30*) % PL3 (20*) % T : INPUT TIME (TOTAL COOKING TIME) * : The numbers in the parentheses are factory settings and can be adjusted. Express Defrost is preset to pause during the sequence when 50% of total defrosting time has passed to check food. Pause timings can also be adjusted. Pause Timing KEY Display Pause Timing 0 0 No pause. 1 1 After 10% of total cooking time. 2 2 After 20% of total cooking time. 3 3 After 30% of total cooking time. 4 4 After 40% of total cooking time. 5 5 After 50% of total cooking time. 6 6 After 60% of total cooking time. 7 7 After 70% of total cooking time. 8 8 After 80% of total cooking time. 9 9 After 90% of total cooking time. START A After ending of each stage * Suppose you want to change the Express Defrost set factory settings to the following: Defrosting Time Power Level STAGE 1 T x 0.30 + 10 sec. 50% STAGE 2 T x 0.15 + 20 sec. 20% STAGE 3 T - STAGE1 - STAGE2 10% Pause When 70% of total defrosting time has Timing passed. Procedure Display CUSTOM EXPRESS x 2 HELP DEFROST 1 Press the CUSTOM (STAGE 1) HELP pad twice within 2 seconds DEF. CHECK and press the EXPRESS DEFROST (A1) pad. (The Express DEF. CHECK Defrost setting (B1) of each phase is shown for 1.5 seconds per 0.3 seconds until the DEF. CHECK (Power Level 1) SELECT/TIME pad is pressed.) DEF. CHECK (STAGE 2) (B2) DEF. CHECK (Power Level 2) DEF. CHECK (STAGE 3) DEF. CHECK (Pause Timing) DEF. CHECK (Power Level 3) DEF. (A2) CHECK DEF. CHECK DEF. CHECK 2 Press the SELECT TIME pad and enter desired SELECT multiplication for A1 at TIME DEF. Stage 1. (Ex: Enter 3,0 for 0.30.) 3 DEF. 0 DEF. 3 Press the SELECT TIME pad and enter desired time for B1 at Stage 1. SELECT TIME DEF. (Ex: Enter 1 for 10 seconds.) 1 DEF. 4 Press the SELECT POWER pad and enter SELECT desired power level for POWER DEF. PL1 at Stage 1. (Ex: Enter 5 for 50%) 5 DEF. EN-17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

EN-17
NOTES:
1. Only Dual Digit Input method can be used when
inputting memory numbers in Multiplication Factor
for Double/Triple Quantity.
2. The multiplication factors can be set from 0.01 to 9.99
for double quantity and
triple quantity.
3. When you want to know the multiplication factor for
triple quantity, press the DOUBLE/TRIPLE QUANTITY
twice at step 1 after pressing the CUSTOM HELP pad
twice.
4. Multiplication Factors for Double/Triple Quantity can
be checked or changed before pressing the STOP/
CLEAR pad to exit for Custom Help Function.
11. Express Defrost Setting
Express Defrosting uses 3 stages to defrost foods
quickly.
The defrosting sequence is preset as follows, but you
can change the setting.
Defrosting Time
Power Level
STAGE
1
T
x A1: (0.20*) + B1: (20*)
sec.
PL1 (40*) %
STAGE
2
T x A2: (0.13*) + B2: (30*)
sec.
PL2 (30*) %
STAGE
3
T - STAGE1 - STAGE2
PL3 (20*) %
Pause
Timing
See the table for The Pause
Timing below (50*)
T : INPUT TIME (TOTAL COOKING TIME)
* :
The numbers in the parentheses are factory settings
and can be adjusted.
Express Defrost is preset to pause during the sequence
when 50% of total defrosting time has passed to check
food. Pause timings can also be adjusted.
Pause Timing
KEY
Display
Pause Timing
0
0
No pause.
1
1
After 10% of total cooking time.
2
2
After 20% of total cooking time.
3
3
After 30% of total cooking time.
4
4
After 40% of total cooking time.
5
5
After 50% of total cooking time.
6
6
After 60% of total cooking time.
7
7
After 70% of total cooking time.
8
8
After 80% of total cooking time.
9
9
After 90% of total cooking time.
START
A
After ending of each stage
3 Press the SELECT TIME
pad and enter desired
time for B1 at Stage 1.
(Ex: Enter 1 for
10 seconds.)
SELECT
TIME
1
DEF.
DEF.
2 Press the SELECT TIME
pad and enter desired
multiplication for A1 at
Stage 1.
(Ex: Enter 3,0 for 0.30.)
DEF.
SELECT
TIME
3
0
DEF.
SELECT
POWER
5
DEF.
DEF.
DEF.
4 Press the SELECT
POWER pad and enter
desired power level for
PL1 at Stage 1.
(Ex: Enter 5 for 50%)
*
Suppose you want to change the Express Defrost set
factory settings to the following:
Defrosting Time
Power
Level
STAGE 1
T x 0.30 + 10 sec.
50%
STAGE 2
T x 0.15 + 20 sec.
20%
STAGE 3
T - STAGE1 - STAGE2
10%
Pause
Timing
When 70% of total defrosting time has
passed.
Procedure
Display
1 Press the CUSTOM
HELP pad twice
within 2 seconds
and press the
EXPRESS DEFROST
pad.
(The Express
Defrost setting
of each phase
is shown for 1.5
seconds per 0.3
seconds until the
SELECT/TIME pad is
pressed.)
x2
CUSTOM
HELP
EXPRESS
DEFROST
CHECK
DEF.
CHECK
DEF.
CHECK
DEF.
CHECK
DEF.
CHECK
DEF.
CHECK
DEF.
CHECK
DEF.
CHECK
DEF.
CHECK
DEF.
CHECK
DEF.
CHECK
DEF.
(STAGE 1)
(A1)
(B1)
(Power Level 1)
(STAGE 2)
(A2)
(B2)
(Power Level 2)
(STAGE 3)
(Pause Timing)
(Power Level 3)