Fix Duct to transition and seal with tape. For both ins tallation method : 10. Wiring the HOOD: WARNIN G: To Avoid Electrical Shock Hazard Turn off power at the service panel before wiring this unit . 120 VAC, 15 or 20 Amp circuit required . ELECTRICAL GROUNDING INSTRUCTIONS THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH 3 WIRES, ONE OF WHICH (GREEN/YELLOW) SERVES TO GROUND THE APPLIANCE. WARNIN G: TO PROTECT YOU AGAINST ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE MUST BE CONNECTED TO THE GROUNDING WIRE IN YOUR HOME ELECTRICAL SYSTEM, AND IT MUST UNDER NO CIRCUNSTANCES BE CUT OR REMOVED. Failure to do so can result in death or electrical shock. t Remove the j-box cover as shown in Figure 5. t If not already done, install 1/2" conduit connector in j-box. t Run black, white, and green wires (#14 AWG) according to the National Electrical Code or CSA Standards and local codes and ordinances . t Connect black, white, and green wires from power supply to black, white, and green/ yellow wires in j-box respectively. t Close j-box cover. Final installation steps 1. Install grease filters, lamps and drip trays as described in the Care & Use section of this manual . Note : Lamps are not supplied, use ONLY 120 Volt, 50 Watt (maximum) 50° halogen light made for a GU10 base, suitable for use in open luminarie . Turn power on at service panel. From control panel Figure 5 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

Fix Duct to transition and seal with tape.
For both ins tallation
method :
10.Wiring
the HOOD:
WARNIN
G:
Electrical
Shock
Hazard
Turn off power at the service
panel before
wiring
this unit .
120 VAC,
15 or 20 Amp circuit
required .
ELECTRICAL
GROUNDING
INSTRUCTIONS
THIS
APPLIANCE
IS FITTED
WITH
AN
ELECTRICAL
JUNCTION
BOX
WITH
3
WIRES,
ONE
OF WHICH
(GREEN/YELLOW)
SERVES
TO GROUND
THE
APPLIANCE.
TO PROTECT
YOU
AGAINST
ELECTRIC
SHOCK,
THE
GREEN AND YELLOW
WIRE
MUST
BE
CONNECTED TO THE
GROUNDING
WIRE
IN
YOUR HOME
ELECTRICAL SYSTEM, AND IT MUST
UNDER NO CIRCUNSTANCES BE CUT OR REMOVED.
Failure
to do so can result
in death or
electrical
shock.
Final
installation
steps
1.
Install grease
filters, lamps and drip trays as
described in the Care & Use section of this
manual .
Note :
Lamps are
not supplied, use ONLY
120
Volt, 50 Watt (maximum)
50° halogen light
made for a GU10
base,
suitable
for use in
open luminarie
.
Turn power on at service panel.
10
To Avoid
WARNIN
G:
Remove
the j-box cover as shown in
Figure
5
.
If not already done,
install 1/2” conduit
connector in j-box.
Run black, white, and green wires (#14
AWG)
according to the National Electrical
Code or CSA
Standards
and local codes and
ordinances .
Connect black, white, and green wires from
power supply to black, white, and green/
yellow wires in j-box respectively.
Close
j-box cover.
Figure
5
From
control
panel