Thermador VCIB54JP Installation Instructions - Page 29
Install the Unit, Connect to Ductwork, Connect Electric, Install Hood Filters and Grease Trays, Test
View all Thermador VCIB54JP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
½" (12.7 mm) X6 each front & back side Figure 36: VCIB Secure Liner Front & Back 6. Install the Unit a) Install the custom insert inside the custom hood. b) Secure to the rear of the frame using six (6) 2" (50.8 mm) mounting screws provided (Figure 37). 7. Connect to Ductwork 8. Connect Electric a) Remove the junction box cover (see Figure 5 on page 11). b) Remove circular knock-out holes located on back side of the insert (see Figure 5 on page 11). c) Connect wiring for blower motor (see blower instructions beginning on page 11). d) Ensure all controls are in the OFF position. Plug electrical cord into grounded outlet. 9. Install Hood Filters and Grease Trays a) Refer to "Installing Grease Trays, Filter Spacers, and Filters" on page 28. 10. Test the installation. a) Test the operation of the blower and the lights. b) Be sure to check for backdraft. With the blower on high, close the windows and doors to the area to ensure that fan does not cause back drafting in any outlet vent for another appliance. 2" (50.8 mm) X6 mounting screws Figure 37: VCIB Rear Screws c) Secure to the sides of the frame using six (6) 2" (50.8 mm) mounting screws provided (Figure 38). 2" (50.8 mm) mounting screws X3 per side Figure 38: VCIB Side Screws English 27