Viking 24" Outdoor Refrigerated Drawers Installation / Use and Care Instructio - Page 8

Product Dimensions

Page 8 highlights

PRODUCT DIMENSIONS MODEL VDUO5241 ROUGH-IN OPENING DIMENSIONS "A" "B" "C" 24" (61 cm) **34" to 35" (86.4 to 88.9 cm) * "D" 237»8" (60.7 cm) CABINET DIMENSIONS "E" "F" "G" 333»4" to 343»4" (85.7 to 88.3 cm) 2323»32" 267»32" (60.2 cm) (66.6 cm) "H" 4613»32" (117.9 cm) "J" 261»4" (66.7 cm) * Depth dimension of rough-in opening may vary depending on each individual installation. To recess entire door "F" dimension plus 1" (2.5 cm) for thickness of power cord plug is required. ** Minimum rough-in opening required is to be larger than the adjusted height of the cabinet. "A" "B" Figure 9 "E" "C" "D" Figure 9a Figure 10 If necessary to gain clearance inside the roughin opening a hole can be cut through the adjacent cabinet and the power cord routed through this hole to a power outlet. Another way to increase the available opening depth is to recess the power outlet into the rear wall to gain the thickness of the power cord plug. Not all recessed outlet boxes will work for this application as they are too narrow, but a recessed outlet box equivalent to Arlington #DVFR1W is recommended for this application, (see Figure 10). 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

8
ROUGH-IN OPENING DIMENSIONS
CABINET DIMENSIONS
MODEL
"A"
"B"
"C"
"D"
"E"
"F"
"G"
"H"
"J"
V
DUO5241
24"
(61 cm)
**34" to 35"
(86.4 to 88.9 cm)
*
23
7
»
8
"
(60.7 cm)
33
3
»
4
" to 34
3
»
4
"
(85.7 to 88.3 cm)
23
23
»
32
"
(60.2 cm)
26
7
»
32
"
(66.6 cm)
46
13
»
32
"
(117.9 cm)
26
1
»
4
"
(66.7 cm)
"A"
"B"
"C"
"D"
"E"
If necessary to gain clearance inside the rough-
in opening a hole can be cut through the adjacent
cabinet and the power cord routed through this hole to
a power outlet. Another way to increase the available
opening depth is to recess the power outlet into the
rear wall to gain the thickness of the power cord
plug. Not all recessed outlet boxes will work for this
application as they are too narrow, but a recessed
outlet box equivalent to Arlington #DVFR1W is
recommended for this application, (see Figure 10).
* Depth dimension of rough-in opening may vary depending on each individual installation. To recess entire door "F"
dimension plus 1" (2.5 cm) for thickness of power cord plug is required.
** Minimum rough-in opening required is to be larger than the adjusted height of the cabinet.
PRODUCT DIMENSIONS
Figure 10
Figure 9
Figure 9a