Westinghouse MT80A THIN Installation Instructions - Page 5

Installation to Solid Concrete or Cinder Block

Page 5 highlights

Installation to Solid Concrete or Cinder Block WARNING • When installing Westinghouse wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity. • Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor. • Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware and components. 1 Make sure that wall plate (A) is level, use it as a template to mark two mounting holes. Drill two 1/4" (6 mm) dia. holes to a minimum depth of 2.5" (64 mm). Insert anchors (H) in holes flush with wall as shown (right). Place wall plate over anchors and secure with two #14 x 2.5" screws (G). Level, then tighten all fasteners. WARNING • Tighten screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power. • Never tighten in excess of 80 in. • lb (9 N.M.). WARNING • Always attach concrete expansion anchors directly to load-bearing concrete. • Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other finishing material. If mounting to concrete surfaces covered with a finishing surface is unavoidable, the finishing surface must be counterbored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws. If plaster/drywall is thicker than 5/8", custom fasteners must be supplied by installer. INCORRECT CORRECT 1 concrete surface H Drill holes and insert anchors (H). 2 A GH Place plate (A) over anchors (H) and secure with screws (G). 3 Tighten all fasteners. A COSONCLIRDETE H CINDER BLOCK wall plate concrete wall plate concrete G CUTAWAY VIEW plaster/ dry wall plaster/ dry wall 5 of 8 ISSUED: 01-17-06 SHEET #: 202-9090-1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

5 of 8
ISSUED: 01-17-06
SHEET #: 202-9090-1
Installation to Solid Concrete or Cinder Block
1
Make sure that wall plate (
A
) is level, use it as a
template to mark two mounting holes. Drill two 1/4"
(6 mm) dia. holes to a minimum depth of 2.5" (64
mm). Insert anchors (
H
) in holes flush with wall as
shown (right). Place wall plate over anchors and
secure with two #14 x 2.5" screws (
G
). Level, then
tighten all fasteners.
When installing Westinghouse wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual con-
crete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a
solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to
avoid breaking out the back of the hole when entering a void or cavity.
Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware
and components.
WARNING
CUTAWAY VIEW
INCORRECT
concrete
surface
1
3
2
Drill holes and insert anchors (
H
).
CORRECT
Place plate (
A
) over anchors (
H
) and secure with screws (
G
).
Tighten all fasteners.
wall
plate
plaster/
dry wall
concrete
wall plate
concrete
plaster/
dry wall
Always attach concrete expansion anchors
directly to
load-bearing concrete.
Never attach concrete expansion anchors to concrete
covered with plaster, drywall, or other finishing mate-
rial. If mounting to concrete surfaces covered with a
finishing surface is unavoidable, the finishing surface
must be counterbored as shown below. Be sure
concrete anchors do not pull away from concrete
when tightening screws. If plaster/drywall is thicker
than 5/8", custom fasteners must be supplied by
installer.
WARNING
A
Tighten screws so that wall plate is firmly attached,
but do not
overtighten. Overtightening can damage
screws, greatly reducing their holding power.
Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
H
G
G
CINDER BLOCK
SOLID
CONCRETE
A
H