Whirlpool GEW9250PT Use and Care Guide - Page 22

Troubleshooting

Page 22 highlights

Moving care WARNING Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. 1. Unplug dryer or disconnect power. Disconnect wiring if dryer is direct wired. 2. Make sure leveling legs are secure in dryer base. 3. Use masking tape to secure dryer door. Changing the Drum Light The dryer light automatically turns on inside the dryer drum when you open the door. To change the drum light 1. Unplug dryer or disconnect power. 2. Open the dryer door. Locate the light bulb cover on the back wall of the dryer. Remove the screw located in the lower right corner of the cover. Remove the cover. 3. Turn bulb counterclockwise. Replace the bulb with a 10-watt appliance bulb only. Replace the cover and secure with the screw. 4. Plug in dryer or reconnect power. TROUBLESHOOTING First try the solutions suggested here and possibly avoid the cost of a service call... Dryer displaying code message s Is the dryer located in a room with temperature below 45ºF (7ºC)? Proper operation of dryer cycles requires temperatures above s "PF" (power failure), check the following: 45ºF (7ºC). Was the drying cycle interrupted by a power failure? Press (and hold) HOLD TO START button to restart the dryer. s Was a cold rinse water used? Was the load very wet? Expect longer drying times with items rinsed in cold water s "E" Variable (E1, E2, E3) service codes: and with items that hold moisture (cottons). Call for service. s Is the load too large and heavy to dry quickly? Clothes are not drying satisfactorily Separate the load to tumble freely. s Check the following: Is the lint screen clogged with lint? Is the exhaust vent or outside exhaust hood clogged with lint, restricting air movement? Run the dryer for 5-10 minutes. Hold your hand under the outside exhaust hood to check air movement. If you do not feel air movement, clean exhaust system of lint or replace exhaust vent with heavy metal or flexible metal vent. See "Installation Instructions." Is the exhaust vent crushed or kinked? Replace with a heavy metal or flexible metal vent. See "Installation Instructions." Has a fuse blown, or has a circuit breaker tripped? Electric dryers use 2 household fuses or breakers. The drum may be turning, but you may not have heat. Has an air cycle been selected? Select the right cycle for the types of garments being dried. See "Cycles." Is the automatic cycle ending early? The load may not be contacting the electronic sensor strips. Level the dryer. Dryer will not run s Check the following: Is the power cord plugged in? Has a fuse blown, or has a circuit breaker tripped? Was a regular fuse used? Use a time-delay fuse. Is the dryer door firmly closed? If not, the time display will blink. Was HOLD TO START firmly pressed and held for at least 1 second? Is a cycle selected? Unusual sounds s Has the dryer had a period of non-use? If the dryer hasn't been used for a while, there may be a thumping sound during the first few minutes of operation. Are fabric softener sheets blocking the grille? Use only one fabric softener sheet and only use it once. 22

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

22
Moving care
1.
Unplug dryer or disconnect power. Disconnect wiring if dryer
is direct wired.
2.
Make sure leveling legs are secure in dryer base.
3.
Use masking tape to secure dryer door.
Changing the Drum Light
The dryer light automatically turns on inside the dryer drum when
you open the door.
To change the drum light
1.
Unplug dryer or disconnect power.
2.
Open the dryer door. Locate the light bulb cover on the back
wall of the dryer. Remove the screw located in the lower right
corner of the cover. Remove the cover.
3.
Turn bulb counterclockwise. Replace the bulb with a 10-watt
appliance bulb only. Replace the cover and secure with the
screw.
4.
Plug in dryer or reconnect power.
TROUBLESHOOTING
First try the solutions suggested here and possibly avoid the cost of a service call...
Dryer displaying code message
“PF” (power failure), check the following:
Was the drying cycle interrupted by a power failure?
Press (and hold) HOLD TO START button to restart the dryer.
“E” Variable (E1, E2, E3) service codes:
Call for service.
Clothes are not drying satisfactorily
Check the following:
Is the lint screen clogged with lint?
Is the exhaust vent or outside exhaust hood clogged with lint,
restricting air movement? Run the dryer for 5-10 minutes.
Hold your hand under the outside exhaust hood to check air
movement. If you do not feel air movement, clean exhaust
system of lint or replace exhaust vent with heavy metal or
flexible metal vent. See
Installation Instructions.
Is the exhaust vent crushed or kinked? Replace with a heavy
metal or flexible metal vent. See
Installation Instructions.
Has a fuse blown, or has a circuit breaker tripped? Electric
dryers use 2 household fuses or breakers. The drum may be
turning, but you may not have heat.
Has an air cycle been selected? Select the right cycle for the
types of garments being dried. See
Cycles.
Is the automatic cycle ending early? The load may not be
contacting the electronic sensor strips. Level the dryer.
Are fabric softener sheets blocking the grille? Use only one
fabric softener sheet and only use it once.
Is the dryer located in a room with temperature below
45ºF (7ºC)?
Proper operation of dryer cycles requires temperatures above
45
º
F (7
º
C).
Was a cold rinse water used? Was the load very wet?
Expect longer drying times with items rinsed in cold water
and with items that hold moisture (cottons).
Is the load too large and heavy to dry quickly?
Separate the load to tumble freely.
Dryer will not run
Check the following:
Is the power cord plugged in?
Has a fuse blown, or has a circuit breaker tripped?
Was a regular fuse used? Use a time-delay fuse.
Is the dryer door firmly closed? If not, the time display will
blink.
Was HOLD TO START firmly pressed and held for at least
1 second?
Is a cycle selected?
Unusual sounds
Has the dryer had a period of non-use?
If the dryer hasn
t been used for a while, there may be a
thumping sound during the first few minutes of operation.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.