Wire Power Supply Cord Strain Relief
View all Whirlpool WCD3090J manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
3. Connect remaining wires 1. Connect neutral (center) wire D B C Connect remaining wires under outer terminal block screws. Tighten screws, tighten strain relief screws. Finally, replace the terminal block cover and secure with the 4 hold-down screws. Now, go to "Level Dryer." 3-Wire Power Supply Cord Strain Relief: IMPORTANT: Use the strain relief supplied with the dryer. Attach power supply cord to strain relief Connect neutral (center) wire (C) of power supply cord under center terminal block screw (B). Tighten screw. 2. Connect remaining wires Put power supply cord through the strain relief. Be sure that the wire insulation on the power supply cord is inside the strain relief. Do not further tighten strain relief screws at this point. 3-Wire Power Supply Cord Connection Use where local codes permit connecting cabinet-ground conductor to neutral wire. Connect remaining wires under outer terminal block screws. Tighten screws, tighten strain relief screws. Finally, replace the terminal block cover and secure with the 4 hold-down screws. Now, go to "Level Dryer." 3-wire receptacle (NEMA-type 10-30R) 3 prong plug Spade terminals with upturned ends 20 Ring terminals