Whirlpool WFG320M0MW Installation Instructions - Page 12

Gas Conversions

Page 12 highlights

GAS CONVERSIONS Gas conversions from Natural gas to Propane gas or from Propane gas to Natural gas must be done by a qualified installer. Propane Gas Conversion WARNING WARNING Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to propane, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column. Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel. Failure to do so can result in death, explosion, or fire. Tip Over Hazard A child or adult can tip the range and be killed. Install anti-tip bracket to floor or wall per installation instructions. Slide range back so rear range foot is engaged in the slot of the anti-tip bracket. Re-engage anti-tip bracket if range is moved. Do not operate range without anti-tip bracket installed and engaged. Failure to follow these instructions can result in death or serious burns to children and adults. 1. Turn manual shut-off valve to the "closed" position. B A C A. Gas supply line B. Manual shut-off valve "closed" position C. To range 2. Unplug range or disconnect power. To Convert Gas Pressure Regulator 1. Open broiler door, and remove broiler rack. The gas pressure regulator is located in the back right-hand corner of the broiler compartment. A A. Gas pressure regulator IMPORTANT: Do not remove the gas pressure regulator. NOTE: Do not remove the spring beneath the cap. 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

12
GAS CONVERSIONS
Gas conversions from Natural gas to Propane gas or from
Propane gas to Natural gas must be done by a qualified installer.
Propane Gas Conversion
1.
Turn manual shut-off valve to the “closed” position.
A. Gas supply line
B. Manual shut-off valve “closed” position
C. To range
2.
Unplug range or disconnect power.
To Convert Gas Pressure Regulator
1.
Open broiler door, and remove broiler rack. The gas pressure
regulator is located in the back right-hand corner of the
broiler compartment.
A. Gas pressure regulator
IMPORTANT:
Do not remove the gas pressure regulator.
NOTE:
Do not remove the spring beneath the cap.
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
A
B
C
A
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.