Xerox 6180N Color Management Guide v3.7 - Page 25
Tips for use of Xerox Qualified Stocks, Calibration process overview
UPC - 095205425307
View all Xerox 6180N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
Stock Management and Calibration Tips for use of Xerox Qualified Stocks Here are some general tips for using Xerox Qualified Stocks: • You are able to modify certain attributes of Xerox Qualified Stocks. Some fundamental attributes cannot be modified, as they affect color processing. The fundamental attributes are: - Name - Color - Weight - Coating - Type (Type, Opacity, Drilled, Modulus) - Finish (iGen3 only) - Color group • Xerox Qualified Stocks cannot be moved from color group to color group. Only User Defined Stocks can be moved and fully edited at will. Calibration process overview Refer to the on-line help for a detailed calibration procedure. Prior to initiating the calibration process, the stock you plan to use for calibration needs to be in a paper tray and that tray programmed for that stock. Begin by calibrating the DTP41 X-Rite Spectrophotometer. NOTE: Calibrating the Spectrophotometer needs only be done once a day. You need the reflective strip card that has the same serial number as the spectrophotometer. Follow the X-Rite instructions. In the DocuSP Color Manager: Associations window select a stock or color group representative. Open the Calibration Wizard and follow the on-screen instructions. When calibration is complete, accept the calibration data. The calibration is now assigned to the stock or color group used for calibration. Color Management Guide 3-3