Xerox 7700DX Service Manual - Page 119
Troubleshooting Power Supplies and Interlocks, Troubleshooting AC Power
View all Xerox 7700DX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 119 highlights
Troubleshooting Power Supplies and Interlocks Troubleshooting AC Power 1. Verify that the AC Input Voltage is present and within specifications. 2. Verify that the Reset button on the GFI is depressed. 3. Reconnect AC power. If the GFI trips immediately with the Power switch Off, disconnect AC power, remove the rear cover and metal shields. Check for shorts in the AC Circuit from the GFI to the Noise Filter, the AC Driver Board and up to the Power Switch. 4. Switch the printer on. If the GFI trips, unplug the printer, remove the fuser, then retest. Disconnect AC power, remove the rear cover and metal shields. Check for shorts in the AC Circuit from the Power Switch back to the AC Driver Board and to the bottom connector on the three Low-voltage Power Supplies. 5. Remove the rear cover and the two metal shields. Connect AC Input and switch the printer On. Check for AC voltage at: ■ J72 on top of the GFI, if not present replace the GFI. ■ Between FS76 and FS77 of the Noise Filter, if not present replace the Noise Filter. ■ Into and out of the Power Switch, if not present replace the Power Switch. ■ The connector at the bottom of the +3.3 VDC, +5 VDC and +24 VDC LVPS, if not present replace the AC Drive Board. Note The GFI, Noise Filter and AC Drive Board are all part of the AC Electrical Chassis, see (RRP 49, on page 7-214). Troubleshooting the Low-voltage Power Supplies +3.3 VDC, +5 VDC and +24 VDC voltages are supplied by individual LVPS boards. The 24 VDC LVPS requires the presence of a +5 VDC enabling signal to operate. Note Before troubleshooting power supply problems, disconnect the Lower Tray Deck or Finisher, if installed, and restart the printer. Verify the problem is still present or refer to the appropriate option troubleshooting section. 1. Verify the printer is plugged in and the GFI is not tripped, Troubleshooting AC Power on page 3-89 2. Remove the Image Processor Board cover and metal plate. Disconnect the Relay Board Power Connector J300. 3. Turn the printer On. Check for +3.3 VDC at J300-1, -2, -3 & -11. Check for +5 VDC at J300-7. If 5 VDC is present check for +24 VDC at J300-9. 4. If no DC voltages are present, Troubleshooting AC Power on page 3-89. 5. If +5 VDC is present but +3.3 VDC is not, Troubleshooting the +3.3 VDC and +5 VDC LVPS on page 3-90. 6. If +3.3 VDC is present but +5 VDC and +24 VDC are not, Troubleshooting the +3.3 VDC and +5 VDC LVPS on page 3-90. 7. If 5 VDC is present but 24 VDC is not, Troubleshooting the +24 VDC LVPS on page 3-90. Phaser 7700 Color Laser Printer Service Manual 3-89