Xerox DC240 x-rite @ DTP32R and DTP32HS Operator's Manual
Xerox DC240 - DocuColor 240 Color Laser Manual
View all Xerox DC240 manuals
Add to My Manuals
Save this manual to your list of manuals |
Xerox DC240 manual content summary:
- Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 1
DTP32HS Auto Scanning Densitometer Operator's Manual - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 2
- Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 3
limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. by turning the equipment off and on, the user is encouraged to try to correct the interference by use this manual for any purpose other than installing, operating, or maintaining this instrument. No part of this manual - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 4
fault Troubleshooting, Service, and General Maintenance 9 Troubleshooting 9 Service Information 10 General Maintenance 10 Cleaning the Reflection Reference 11 Technical Information 12 Instrument Reset 12 Drive Wheels Rotation Timer 12 Technical Notes 12 Instrument Specifications - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 5
, and digitally connected color copiers. The DTP32HS densitometer is a "drop-in" replacement for the X-Rite DTP32R instrument. This manual covers the installation, basic operation and maintenance of the instrument. Specific instructions for using the instrument with your third-party software program - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 6
computer's Serial ports. For attachment to a Mac Mini-DIN 8 Serial Port, you need to use the optional adapter (P/N SE108-DB9PA-01). 1. before installing interface cabling. 2. Connect the interface cable as shown. CAUTION: Use only the 100-240VAC input, +12VDC output Switching Power Supply to power - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 7
before it is taken in by the drive motor. More specifically, a strip cannot be fed into the instrument too more times). If you are experiencing any strip-feeding problems, observe how fast the motor is moving the strip ready for use. • Fast Flashing Green-instrument calibration failed. Error/Reset - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 8
DTP32HS DENSITOMETER Strip Positioning and Patch Requirements The strip width must extend a minimum of 0.75" (19mm) to the left of the alignment mark (optical path) when measuring. This ensures the read switch is activated when the strip is inserted into the instrument. TOP VIEW Alignment Mark 0.75 - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 9
DTP32HS DENSITOMETER Calibration Frequency of Calibration Your DTP32HS should be calibrated weekly. Refer to the following procedure for details on the calibration process. Reflection Reference Handling Handle the reflection reference by the edges. Make sure that the reflection reference is free of - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 10
software program that you are using with your instrument. All applications that utilize this instrument must be running during measurements. • The strip must have at least a 1.2″ (30.5mm) leader before the leading edge of the first step. Contact X-Rite Applications Support cover), guide the - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 11
DENSITOMETER Troubleshooting, Service, and General Maintenance Troubleshooting The DTP32HS is used with a number of third party software vendors. To get the most specialized technical assistance, you should first contact the technical service representative for the specific third-party software that - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 12
. The customer shall pay shipping and repair cost to the authorized service center, and the instrument shall be submitted in the original carton, wiped clean with a cloth dampened in water or mild cleaner. NOTE: DO NOT use any solvents to the clean the instrument, this will cause damage to the cover - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 13
protective case when finished. Always handle the calibration reference by the edges. If required, a new calibration reference can be ordered from X-Rite. Order calibration reference part number DTP32HS-100-KIT. 11 - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 14
the correct configuration for your software is then restored. The The instruments rubber drive wheels may develop temporary flat spots if the instrument after a 12 hour, non-use period. A reading or computer command the instrument functions properly and user-configurable settings are restored to - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 15
DTP32HS DENSITOMETER Instrument Specifications - Pending General Interface/ Protocol (as described in X-Rite DTP RCI manual I/O port: patented bi-directional RS-232 at - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 16
No. 1010.1-92 CENELEC IEC (EN) 61010-1 Design and specifications subject to change without notice. Standard Accessories Calibration Reference DTP Supply Line Cord (North America) Line Cord (Europe) Optional Accessories Mac Serial Adapter P/N SE108-DB9PA-01 25-pin Serial Adapter ......... P/N SE108 - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 17
, keyboard, and strip guide. The DTP34HS does not. In order to use the DTP34HS product where a software application expects the Cal Strip using menus, as is required for the DTP32 product. A calibration can be initiated like any other reading. Please see the calibration section in the manual - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 18
the initial barcode as being part of a set-up barcode use the Set-up barcodes if instructed to manually set-up your instrument. This will avoid changing configurations that may cause the densitometer and your software to cease communicating. If this does happen reference the Troubleshooting, Service - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 19
Baud Rate Configuration First scan this bar code and then scan "1200", "2400", "4800", "9600", or "19200" baud rate codes on the following five pages for the desired setting. - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 20
Baud Rate 1200 - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 21
Baud Rate 2400 - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 22
Baud Rate 4800 - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 23
Baud Rate 9600 - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 24
Baud Rate 19200 - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 25
Auto Transmit Configuration First scan this bar code and then scan the "On" or "Off" code on the following two pages for the desired setting. - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 26
Auto Transmit On - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 27
Auto Transmit Off - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 28
Decimal Point Configuration First scan this bar code and then scan the "On" or "Off" code on the following two pages for the desired setting. - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 29
Decimal Point On - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 30
Decimal Point Off - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 31
Times Ten Configuration First scan this bar code and then scan the "On" or "Off" code on the following two pages for the desired setting. - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 32
Times Ten On - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 33
Times Ten Off - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 34
Data After Pass Configuration First scan this bar code and then scan the "On" or "Off" code on the following two pages for the desired setting. - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 35
Data After Pass On - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 36
Data After Pass Off - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 37
Delimiter Configuration First scan this bar code and then scan the "Carriage Return" or "Carriage Return and Line Feed" code on the following two pages for the desired setting. - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 38
Delimiter CR - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 39
Delimiter CR/LF - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 40
Separator Configuration First scan this bar code and then scan the "Space", "Comma", "Tab", "Carriage Return", or "Carriage Return and Line Feed" code on the following five pages for the desired setting. - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 41
Separator Space - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 42
Separator Comma - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 43
Separator Tab - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 44
Separator CR - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 45
Separator CR/LF - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 46
Min/Max Configuration First scan this bar code and then scan the "Off", "Min", "Max", or "Min and Max" code on the following four pages for the desired setting. - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 47
Min/Max Off - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 48
Min/Max Min - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 49
Min/Max Max - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 50
Min/Max Min/Max - Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 51
- Xerox DC240 | x-rite @ DTP32R and DTP32HS Operator's Manual - Page 52
X-Rite, Incorporated - World Headquarters 3100 44th Street S.W. • Grandville, Michigan 49418 • USA www.x-rite.com Tel: 1-888-826-3059 • Fax: 1-888-826-3061 or (616) 534-0726 International Numbers Tel: 1-888-826-3039 or (616) 534-7663 • Fax: (616) 534-0723 X-Rite GmbH Stollwerckstraße 32 • 51149 Köln
DTP32HS
Auto Scanning Densitometer
Operator’s Manual