MIDI Functions MIDI Transmit & Receive Channel Selection MIDI OUT DOU-10 MIDI IN MIDI THRU MIDI IN Tone Generator (Set to receive on MIDI channel 2) Clavinova (Set to receive on MIDI channel 1) The MIDI system allows transmission and reception of MIDI data on 16 different channels. Multiple channels have been implemented to allow selective control of certain instruments or devices connected in series. For example, a single MIDI sequence recorder could be used to "play" two different instruments or tone generators. One of the instruments or tone generators could be set to receive only on channel 1, while the other is set to receive on channel 2. In this situation the first instrument or tone generator will respond only to channel-1 information transmitted by the sequence recorder, while the second instrument or tone generator will respond only to channel-2 information. This allows the sequence recorder to "play" two completely different parts on the receiving instruments or tone generators. In any MIDI control setup, the MIDI channels of the transmitting and receiving equipment must be matched for proper data transfer. An "OMNI" receive mode is also available, which allows reception on all 16 MIDI channels. In the OMNI mode it is not necessary to match the receive channel of the receiving device to the transmit channel of the transmitting device (except when receiving mode messages). q Setting the Clavinova MIDI Channels MIDI/TRANSPOSE C1 D#2 C 4 2 4 7 9 11 14 16 24 E5 D#5 7 9 11 14 16 1 3 5 6 8 10 12 13 15 1 3 5 6 8 10 12 13 15 For setting the transmit For setting the receive channel. (C1 ~ D#2) channel. (C4 ~ D#5) For OMNI mode Z Press and hold the [MIDI/TRANSPOSE] button. X Press the key on the keyboard corresponding to the desired MIDI transmit or receive channel.* C Release the [MIDI/TRANSPOSE] button. * Keys C1 through D#2 on the keyboard are used to set the MIDI transmit channel, and keys C4 through D#5 are used to turn the OMNI mode OFF and set the MIDI receive channel as shown in the illustration to the left. The E5 key sets the OMNI receive mode and basic receive channel 1. NOTE • When the power is initially turned ON, MIDI receive is set to the OMNI mode and the transmit channel is set to 1. MIDI Transmit Transpose ... This function allows the MIDI note data transmitted by the Clavinova to be transposed up or down in semitone increments by up to plus or minus 6 semitones. The pitch of the Clavinova itself is not affected. q Setting the MIDI Transpose Function MIDI/TRANSPOSE F#5 C6 F#6 -6 -4 -2 +1 +3 +6 -5 -3 -1 0 +2 +4 +5 Z Press and hold the [MIDI/TRANSPOSE] button. X Press the key on the keyboard corresponding to the desired amount of transposition.* C Release the [MIDI/TRANSPOSE] button. * Keys F#5 through F#6 on the keyboard are used to set the MIDI transmit transpose function as shown in the illustration to the left. NOTE • When the power is turned ON, MIDI transmit transpose is set to 0 (no transposition). Other MIDI Functions The MIDI functions listed to the right are engaged by holding down the [MIDI/TRANSPOSE] button and pressing the corresponding voice selector. Full details are given in the following pages. MIDI FUNCTION CHART Function Local Control ON/OFF Program Change ON/OFF Control Change ON/OFF Multi-Timbre Mode MIDI Split & Left Local OFF CLP-311 Voice Selector [PIANO] [CLAVI. TONE] [E. PIANO] [HARPSICHORD] [PIPE ORGAN] 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

14
MIDI Functions
MIDI Transmit & Receive Channel Selection
..................................................................................................
Tone Generator
MIDI IN
MIDI IN
MIDI THRU
DOU-10
MIDI OUT
Clavinova
Setting the Clavinova MIDI Channels
(Set to receive on MIDI
channel 2)
(Set to receive on MIDI channel 1)
C
1
D
#
2
C
4
D
#
5
1
3
5
6
8 10 12 13 15
2
4
7
9
11
14 16
1
3
5
6
8 10 12 13 15
2
4
7
9
11
14 16
E
5
MIDI/TRANSPOSE
For setting the transmit
channel. (C1 ~ D
#
2)
For setting the receive
channel. (C4 ~ D
#
5)
For OMNI mode
Z
Press and hold the
[MIDI/TRANSPOSE]
button.
X
Press the key on the keyboard corresponding to the desired MIDI
transmit or receive channel.*
C
Release the
[MIDI/TRANSPOSE]
button.
*
Keys
C1
through
D
#
2
on the keyboard are used to set the MIDI
transmit channel, and keys
C4
through
D
#
5
are used to turn the
OMNI mode OFF and set the MIDI receive channel as shown in
the illustration to the left. The
E5
key sets the OMNI receive
mode and basic receive channel 1.
NOTE
When the power is initially turned ON, MIDI receive is
set to the OMNI mode and the transmit channel is set
to 1.
The MIDI system allows transmission and reception of MIDI data
on 16 different channels. Multiple channels have been implemented
to allow selective control of certain instruments or devices connected
in series. For example, a single MIDI sequence recorder could be
used to “play” two different instruments or tone generators. One of
the instruments or tone generators could be set to receive only on
channel 1, while the other is set to receive on channel 2. In this
situation the first instrument or tone generator will respond only to
channel-1 information transmitted by the sequence recorder, while the
second instrument or tone generator will respond only to channel-2
information. This allows the sequence recorder to “play” two
completely different parts on the receiving instruments or tone
generators.
In any MIDI control setup, the MIDI channels of the transmitting
and receiving equipment must be matched for proper data transfer. An
“OMNI” receive mode is also available, which allows reception on
all 16 MIDI channels. In the OMNI mode it is not necessary to match
the receive channel of the receiving device to the transmit channel of
the transmitting device (except when receiving mode messages).
Other MIDI Functions
The MIDI functions listed to the right are engaged by holding
down the
[MIDI/TRANSPOSE]
button and pressing the correspond-
ing voice selector. Full details are given in the following pages.
Function
CLP-311 Voice Selector
Local Control ON/OFF
[PIANO]
Program Change ON/OFF
[CLAVI. TONE]
Control Change ON/OFF
[E. PIANO]
Multi-Timbre Mode
[HARPSICHORD]
MIDI Split & Left Local OFF
[PIPE ORGAN]
MIDI FUNCTION CHART
MIDI Transmit Transpose
.....................................................................................................................................................
This function allows the MIDI note data transmitted by the
Clavinova to be transposed up or down in semitone increments by up
to plus or minus 6 semitones. The pitch of the Clavinova itself is not
affected.
Setting the MIDI Transpose Function
MIDI/TRANSPOSE
C
6
F
#
5
F
#
6
-6 -4 -2
+1 +
3
+
6
+5
+4
+2
0
-1
-3
-5
Z
Press and hold the
[MIDI/TRANSPOSE]
button.
X
Press the key on the keyboard corresponding to the desired
amount of transposition.*
C
Release the
[MIDI/TRANSPOSE]
button.
*
Keys
F
#
5
through
F
#
6
on the keyboard are used to set the MIDI
transmit transpose function as shown in the illustration to the left.
NOTE
When the power is turned ON, MIDI transmit transpose
is set to 0 (no transposition).