Yamaha CVP-96 Owner's Manual - Page 86

Recalling the Registered Panel Settings

Page 86 highlights

Registrations (Registering/Recalling Panel Setups CRegister the panel setup While holding the [MEMORY] button, simultaneously press one of the REGISTRATION [1] - [4] buttons. Any data that was previously in the selected location is erased and replaced by the new settings. The corresponding Registration number (bank/button number) and the Registration name will appear below and to the right of the style name in the main display. "A-1 (number 1 of bank A)" and "REGIST A-1" (temporary Registration name) will appear next to the RE mark. REGISTRATION 1 2 3 4 BANK MEMORY BANK FREEZE Registration • Range: Bank: A- E, Button: 1 - 4 • Basic setting: Pre-programmed set- tings are registered in all Registration numbers. • Backup of last settings: ON • The REGISTRATION [NAME] pop-up display appears when pressing the [MEMORY] button; however, this display is not necessary in registering the panel setup. • The data for each Registration or a group of 20 Registrations can be saved to floppy disk, for future recall. (See page 139.) Registered Registration number and name Recalling the Registered Panel Settings Press the BANK [-] [+] buttons as described above (in step #2) to select the bank corresponding to the desired Registration. Then, simply press the corresponding REGISTRATION [1] - [4] button to recall the desired Registration. The recalled Registration number (bank/button number) and the Registration name will appear below and to the right of the style name in the LCD display. A pencil icon appears at the right of the Registration name in the display as soon as any change is made to the panel buttons or settings. In other words, if the pencil icon is displayed, the current panel settings are different from those stored in memory. • Only selecting a different bank will not change the Registration settings. • The Registration settings are recalled only when one of the REGISTRATION [1] - [4] buttons is pressed. • If the Left Pedal function is set to "Registration" (see page 133), the left pedal can be used to step through the Registrations, letting you recall a different Registration each time the pedal is pressed. However, other left pedal settings assigned to each Registration cannot be recalled in this case. 84 CVP-98/96/600 Edit Symbol 84

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164

84
84
CVP-98/96/600
C
Register the panel setup.
.........................................................................
While holding the
[MEMORY]
button, simultaneously press one of
the REGISTRATION
[1]
[4]
buttons.
Any data that was previously in
the selected location is erased and replaced by the new settings.
The
corresponding Registration number (bank/button number) and the Regis-
tration name will appear below and to the right of the style name in the
main display. “A-1 (number 1 of bank A)” and “REGIST A-1” (tempo-
rary Registration name) will appear next to the RE mark.
Registration
Range: Bank: A— E, Button: 1 — 4
Basic setting: Pre-programmed set-
tings are registered in all Registration
numbers.
Backup of last settings:
ON
The REGISTRATION [NAME] pop-up
display appears when pressing the
[MEMORY] button; however, this
display is not necessary in registering
the panel setup.
The data for each Registration or a
group of 20 Registrations can be
saved to floppy disk, for future recall.
(See page 139.)
Press the BANK
[–] [+]
buttons as described above (in step #2) to
select the bank corresponding to the desired Registration.
Then, simply
press the corresponding REGISTRATION
[1]
[4]
button to recall the
desired Registration.
The recalled Registration number (bank/button
number) and the Registration name will appear below and to the right of
the style name in the LCD display.
A pencil icon appears at the right of
the Registration name in the display as soon as any change is made to the
panel buttons or settings.
In other words, if the pencil icon is displayed,
the current panel settings are different from those stored in memory.
Only selecting a different bank will not
change the Registration settings.
The Registration settings are recalled
only when one of the REGISTRATION
[1] — [4] buttons is pressed.
If the Left Pedal function is set to “Reg-
istration” (see page 133), the left pedal
can be used to step through the Regis-
trations, letting you recall a different
Registration each time the pedal is
pressed.
However, other left pedal
settings assigned to each Registration
cannot be recalled in this case.
Registered Registration
number and name
Edit Symbol
Recalling the Registered Panel Settings
Registrations
(Registering/Recalling Panel Setups)
1
2
3
4
BANK
BANK
MEMORY
FREEZE
REGISTRATION