Yamaha PM5000 Owner's Manual - Page 45
The Cue Stack Function, Cue Stack Flow, Input Channel
View all Yamaha PM5000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
The cue points for all masters can be switched at once. To monitor the pre-master-fader signals engage the [MASTER PFL] switch, or disengage it to monitor the post-monitor-fader signals. In the latter case if the "PRE ON" cue point is selected (before the master [ON] switches - page 69) monitoring is possible even when output to the house speakers is off. [MASTER PFL] Switch [LAST CUE] Switch Monitor Control Section The Cue Stack Function All current [CUE] switch settings are normally disengaged if a [CUE] switch in a different section is engaged. When all panel [CUE] switches are turned off monitor output reverts to the main stereo program or 2-track input signal. In some situations, however, the PM5000 "cue stack" function applies. If, for example, cue monitoring is engaged for the master out section, then the VCA section, and then the input channel section (master out ➝ VCA ➝ input channel), and then all of the [CUE] switches in one of the latter sections are disengaged, the cue status of the preceding section will be restored. As described above cue monitoring can be active for one section at a time. Normally when multiple [CUE] switches in a section are engaged the corresponding signals are all sent to the monitor outputs (MIX CUE mode). When the [LAST CUE] switch is engaged, however, only the last [CUE] switch engaged in any one section will be active (LAST CUE mode). NOTE All active [CUE] switches will be disengaged when switching between the MIX CUE and LAST CUE modes. A neat "trick" to disengage all cues at once, therefore, is to engage and then immediately disengage the [LAST CUE] switch. Input Channel Master Out VCA Cue Stack Flow • Master Out ➝ VCA ➝ Input Channel • Master Out ➝ VCA If all VCA [CUE] switches are disengaged the preceding master out section cue status is restored. • VCA ➝ Input Channel If all input channel [CUE] switches are disengaged the preceding VCA section cue status is restored. • Master Out ➝ Input Channel If all input channel [CUE] switches are disengaged the preceding master out section cue status is restored. The cue stack function will not work if the above order is reversed (input channel ➝ VCA ➝ master out), or if a [CUE] switch in any other section is engaged. 43