3Com 3C16980 User Guide - Page 43

Technical Specifications, S - weight

Page 43 highlights

C TECHNICAL SPECIFICATIONS Physical Dimensions Environmental Requirements Operating Temperature Storage Temperature Operating Humidity Standards Safety Agency Certifications EMC Emissions Immunity Heat Dissipation Power Supply AC Line Frequency Input Voltage Options Current Rating Height: 76mm (3.0 in.) x Width: 483mm (19.0 in.) x Depth 300mm (12.0 in.) Weight: 4kg (8.8lbs) 0° to 50°C (32° to 122°F) -10° to +70°C (14° to 158°F) 10-95% relative humidity, non-condensing EN60068 (IEC68) UL 1950, EN60950, CSA 22.2 No. 950, IEC 950 EN55022 Class B*, FCC Part 15 subpart B Class A, ICES-003 Class A, VCCI Class B*, AS/NZS 3548 Class B*, CNS 13438 Class A * Category 5 screened cables must be used to ensure compliance with the class B requirements of this standard. The use of unscreened cables (category 3 or 5 for 10BASE-T ports or category 5 for 100BASE-TX ports) complies with the class A requirements. EN50082-1 171 watts maximum (583 BTU/hour maximum) 50/60Hz 90-240 VAC 3amps (maximum) (continued)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

C
T
ECHNICAL
S
PECIFICATIONS
Physical Dimensions
Height: 76mm (3.0 in.) x Width: 483mm (19.0 in.) x Depth 300mm (12.0 in.)
Weight: 4kg (8.8lbs)
Environmental Requirements
Operating Temperature
0° to 50°C (32° to 122°F)
Storage Temperature
–10° to +70°C (14° to 158°F)
Operating Humidity
10–95% relative humidity, non-condensing
Standards
EN60068 (IEC68)
Safety
Agency Certifications
UL 1950, EN60950, CSA 22.2 No. 950, IEC 950
EMC
Emissions
EN55022 Class B*, FCC Part 15 subpart B Class A, ICES-003 Class A, VCCI Class
B*, AS/NZS 3548 Class B*, CNS 13438 Class A
* Category 5 screened cables must be used to ensure compliance with the class
B requirements of this standard. The use of unscreened cables (category 3 or 5
for 10BASE-T ports or category 5 for 100BASE-TX ports) complies with the class
A requirements.
Immunity
EN50082-1
Heat Dissipation
171 watts maximum (583 BTU/hour maximum)
Power Supply
AC Line Frequency
50/60Hz
Input Voltage Options
90–240 VAC
Current Rating
3amps (maximum)
(continued)