3M™ Display M2256PW User Guide 35 Response: Copyright © 2010 3M. All rights reserved. Description: This command is used to get copyright information. Mode Down Up Syntax: MDU Response: 0 Positive response. Description: Limits touch reports to touchdown and liftoff events only. Mode Inactive Syntax: MI Response: 0 Positive response. Description: Turns off touch reports. Mode Stream Syntax: MS Response: 0 Positive response. The controller will respond with acknowledge (ACK) for compatibility. This format is the only format supported by this controller. Description: This is the default mode of operation at power up. Touch reports include touchdown and liftoff events as well as continuing touches. Name Command Syntax: NM Response: 0 Positive response. Description: Returns a name string Null Command Syntax: Z Response: 0 Positive response. Description: Queries the controller and waits for a response. Use Z to determine that you are communicating with the controller or to make sure that a utility is communicating with the controller. Using this command does not affect the controller's current operating parameters. 3M Touch Systems, Inc. Proprietary Information