3Ware 8506-4LP User Guide - Page 110
Aen 004h, Aen_rebuild_fail, Aen_incomp_unit, Aen_init_done, Aen_unclean_shutdown, Ignore
UPC - 693494850642
View all 3Ware 8506-4LP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 110 highlights
Troubleshooting: Problems and Solutions AEN 004h AEN_REBUILD_FAIL The ATA RAID controller was unable to complete a rebuild operation. This error can be caused by drive errors on either the source or the destination of the rebuild. However, due to ATA drives ability to reallocate sectors on write errors, the rebuild failure is most likely caused by the source drive of the rebuild detecting some sort of read error. The default operation of the ATA RAID controller is to abort a rebuild if an error is encountered. If it is desired to continue on error, the Ignore errors on rebuild radio button can be checked prior to initiating a rebuild. AEN 005h AEN_REBUILD_DONE The ATA RAID controller has successfully completed a rebuild. The completion of the rebuild changes the state of the array from rebuilding to OK. The data is now redundant. AEN 006h AEN_INCOMP_UNIT At power on initialization time, the ATA RAID controller performs a "rollcall" of all drives attached to the card. After detection of the drives, the ATA RAID controller then uses an internal algorithm to logically connect drives that belong to the same array. If after rollcall a member of an array is not found, the INCOMPLETE UNIT AEN is sent. Examples of incomplete units are as follows: ■ 4 drive RAID 5 with 1 drive missing. ■ 2 drive RAID 1 with 1 drive missing. Replacing the missing or dead drive and initiating a rebuild will change the state of the array from an incomplete unit to OK. AEN 007h AEN_INIT_DONE The ATA RAID controller has completed the initialization sequence and performs the initialization step at array creation time of RAID levels 1, 10 and 5. For RAID 5, the data on the array is read and the resultant parity is written to the parity area on the array. For RAID 1 and 10, one half of the mirror is copied to the other half (mirrors are synchronized). AEN 008h AEN_UNCLEAN_SHUTDOWN The ATA RAID controller has the ability to detect if the system has been shutdown via the standard shutdown mechanism of the operating system (clean shutdown). If the system loses power or is reset without going through the normal shutdown procedure, it is possible that the data on a redundant array may be out of synchronization. The unclean shutdown detection will detect 102 3ware Escalade ATA RAID Controller User Guide