ASRock B660M Phantom Gaming 4 User Manual - Page 66

MRC Training Respond Time, ASRock Second Timing Optimization

Page 66 highlights

B660M Phantom Gaming 4 ODT NOM (A1) Use this to change ODT (CH A1) Auto/Manual settings. The default is [Auto]. ODT NOM (A2) Use this to change ODT (CH A2) Auto/Manual settings. The default is [Auto]. ODT NOM (B1) Use this to change ODT (CH B1) Auto/Manual settings. The default is [Auto]. ODT NOM (B2) Use this to change ODT (CH B2) Auto/Manual settings. The default is [Auto]. ODT PARK (A1) Configure the memory on die termination resistors' PARK for channel A1. ODT PARK (A2) Configure the memory on die termination resistors' PARK for channel A2. ODT PARK (B1) Configure the memory on die termination resistors' PARK for channel B1. ODT PARK (B2) Configure the memory on die termination resistors' PARK for channel B2. Advanced Setting ASRock Timing Optimization Configure the fast path through the MRC. ASRock Second Timing Optimization Configure the second fast path through the MRC. MRC Training Respond Time Configure the MRC Training Respond Time. Realtime Memory Timing Configure the realtime memory timings. [Enabled] The system will allow performing realtime memory timing changes after MRC_DONE. 59 English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

59
English
B660M Phantom Gaming 4
ODT NOM (A1)
Use this to change ODT (CH A1) Auto/Manual settings. °e default is [Auto].
ODT NOM (A2)
Use this to change ODT (CH A2) Auto/Manual settings. °e default is [Auto].
ODT NOM (B1)
Use this to change ODT (CH B1) Auto/Manual settings. °e default is [Auto].
ODT NOM (B2)
Use this to change ODT (CH B2) Auto/Manual settings. °e default is [Auto].
ODT PARK (A1)
Configure the memory on die termination resistors' PARK for channel A1.
ODT PARK (A2)
Configure the memory on die termination resistors' PARK for channel A2.
ODT PARK (B1)
Configure the memory on die termination resistors' PARK for channel B1.
ODT PARK (B2)
Configure the memory on die termination resistors' PARK for channel B2.
Advanced Setting
ASRock Timing Optimization
Configure the fast path through the MRC.
ASRock Second Timing Optimization
Configure the second fast path through the MRC.
MRC Training Respond Time
Configure the MRC Training Respond Time.
Realtime Memory Timing
Configure the realtime memory timings.
[Enabled] °e system will allow performing realtime memory timing changes aſter
MRC_DONE.