ASRock H610M-HDV/M.2 R2.0 User Manual - Page 60

Offset Prefix, Ring Voltage Mode, Extra Turbo Voltage, VF Offset Mode

Page 60 highlights

H610M-HDV/M.2 R2.0 H610M-HVS/M.2 R2.0 Specifies the offset voltage applied to the IA Core domain. This voltage is specified in millivolts. Offset Prefix Sets the offset value as positive or negative. Ring Voltage Mode Selects between adaptive and Override Voltage modes. In Override Mode the voltage selected will be applied over all operating frequencies. In Adaptive Mode the voltage is interpolated only in turbo mode. Uses Mailbox 0SR 0x150, cmd 0x10, 0x11. Extra Turbo Voltage Specifies the extra turbo voltage applied while ring is operating in turbo mode. Uses Mailbox MSR 0x150, cmd 0x10, 0x11. Range 0-2000 mV. VF Offset Mode Selects between Legacy and Selection modes. Need Reset System after enabling OverClocking Feature to initialize the default value. In Legacy Mode, setting a global offset for the entire VF curve. In Selection modes, setting a selected VF point. Ring Voltage Offset Specifies the Offset Voltage applied to the Ring domain. This voltage is specified in millivolts. Uses Mailbox MSR 0x150, cmd 0x11. Range -500 to 500 mV. Offset Prefix Sets the offset value as positive or negative. GT Voltage Mode Selects between adaptive and Override Voltage modes. In Override Mode the voltage selected will be applied over all operating frequencies. In Adaptive Mode the voltage is interpolated only in turbo mode. Uses Mailbox 0SR 0x150, cmd 0x10, 0x11. Extra Turbo Voltage Specifies the extra turbo voltage applied while GT is operating in turbo mode. Uses Mailbox MSR 0x150, cmd 0x10, 0x11. Range 0-2000 mV. GT Voltage Offset Specifies the Offset Voltage applied to the GT domain. This voltage is specified in millivolts. Uses Mailbox MSR 0x150, cmd 0x11. Range -500 to 500 mV. 53 English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83

53
English
H610M-HDV/M.2 R2.0
H610M-HVS/M.2 R2.0
Specifies the offset voltage applied to the IA Core domain. °is voltage is specified
in millivolts.
Offset Prefix
Sets the offset value as positive or negative.
Ring Voltage Mode
Selects between adaptive and Override Voltage modes. In Override Mode the
voltage selected will be applied over all operating frequencies. In Adaptive Mode
the voltage is interpolated only in turbo mode. Uses Mailbox 0SR 0x150, cmd 0x10,
0x11.
Extra Turbo Voltage
Specifies the extra turbo voltage applied while ring is operating in turbo mode. Uses
Mailbox MSR 0x150, cmd 0x10, 0x11. Range 0-2000 mV.
VF Offset Mode
Selects between Legacy and Selection modes. Need Reset System aſter enabling
OverClocking Feature to initialize the default value. In Legacy Mode, setting a
global offset for the entire VF curve. In Selection modes, setting a selected VF point.
Ring Voltage Offset
Specifies the Offset Voltage applied to the Ring domain. °is voltage is specified in
millivolts. Uses Mailbox MSR 0x150, cmd 0x11. Range -500 to 500 mV.
Offset Prefix
Sets the offset value as positive or negative.
GT Voltage Mode
Selects between adaptive and Override Voltage modes. In Override Mode the
voltage selected will be applied over all operating frequencies. In Adaptive Mode
the voltage is interpolated only in turbo mode. Uses Mailbox 0SR 0x150, cmd 0x10,
0x11.
Extra Turbo Voltage
Specifies the extra turbo voltage applied while GT is operating in turbo mode. Uses
Mailbox MSR 0x150, cmd 0x10, 0x11. Range 0-2000 mV.
GT Voltage Offset
Specifies the Offset Voltage applied to the GT domain. °is voltage is specified in
millivolts. Uses Mailbox MSR 0x150, cmd 0x11. Range -500 to 500 mV.