ASRock K7S41GX User Manual - Page 15

FID Jumpers - bios update

Page 15 highlights

Clear CMOS (CLRCMOS1, solder points) (see p.7/p.8 No. 11) solder points (CLRCMOS2, 2-pin jumper) (see p.7/p.8 No. 12) 2-pin jumper Note: CLRCMOS1 and CLRCMOS2 allow you to clear the data in CMOS. The data in CMOS includes system setup information such as system password, date, time, and system setup parameters. There are 2 ways for you to clear and reset the system parameters to the default setup. Please turn off the computer and unplug the power cord, then you may either short the solder points on CLRCMOS1 by using metal material, e.g., a paper clip for 3 seconds; or you may use a jumper cap to short the pin on CLRCMOS2 for 3 seconds. Please remember to remove the paper clip or the jumper cap after clearing the CMOS. If you need to clear the CMOS when you just finish updating the BIOS, you must boot up the system first, and then shut it down before you do the clear-CMOS action. FID Jumpers (FID0, FID1, FID2, FID3, FID4) (see p.7/p.8 No. 30) 1 FID0 1 FID1 1 FID2 1 FID3 1 FID4 Note: The set of FID jumpers are only for advanced users to adjust the multiplier of CPU. Please follow the table below to adjust the multiplier of CPU. However, the system will work well without the adjustment of multiplier. You do not have to adjust the multiplier for normal usage. Multiplier 5x 5.5x 6x 6.5x 7x 7.5x 8x 8.5x 9x 9.5x 10x 10.5x 11x 11.5x 12x 12.5x 13x 13.5x 14x 15x 16x 16.5x 17x 18x 19x 20x 21x 22x 23x 24x FID0 1-2 2-3 1-2 2-3 1-2 2-3 1-2 2-3 1-2 2-3 1-2 2-3 1-2 2-3 1-2 2-3 1-2 2-3 1-2 1-2 1-2 2-3 1-2 2-3 2-3 2-3 2-3 2-3 1-2 2-3 FID1 1-2 1-2 2-3 2-3 1-2 1-2 2-3 2-3 1-2 1-2 2-3 2-3 1-2 1-2 2-3 2-3 1-2 1-2 2-3 1-2 2-3 2-3 1-2 1-2 1-2 2-3 2-3 1-2 2-3 2-3 FID2 2-3 2-3 2-3 2-3 1-2 1-2 1-2 1-2 2-3 2-3 2-3 2-3 1-2 1-2 1-2 1-2 2-3 2-3 2-3 1-2 1-2 1-2 2-3 2-3 1-2 1-2 2-3 1-2 2-3 2-3 FID3 1-2 1-2 1-2 1-2 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 1-2 1-2 1-2 1-2 1-2 1-2 1-2 2-3 2-3 2-3 2-3 2-3 1-2 1-2 1-2 2-3 2-3 2-3 FID4 1-2 1-2 1-2 1-2 1-2 1-2 1-2 1-2 1-2 1-2 1-2 1-2 1-2 1-2 1-2 1-2 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31

15
solder
points
2-pin
jumper
Clear CMOS
(CLRCMOS1, solder points)
(CLRCMOS2, 2-pin jumper)
(see p.7/p.8
No. 11)
(see p.7/p.8
No. 12)
Note:
CLRCMOS1 and CLRCMOS2 allow you to clear the data in CMOS. The data in CMOS
includes system setup information such as system password, date, time, and system
setup parameters. There are 2 ways for you to clear and reset the system parameters to
the default setup. Please turn off the computer and unplug the power cord, then you may
either short the solder points on CLRCMOS1 by using metal material, e.g., a paper clip for
3 seconds; or you may use a jumper cap to short the pin on CLRCMOS2 for 3 seconds.
Please remember to remove the paper clip or the jumper cap after clearing the CMOS. If
you need to clear the CMOS when you just finish updating the BIOS, you must boot up the
system first, and then shut it down before you do the clear-CMOS action.
FID Jumpers
(FID0, FID1, FID2, FID3, FID4)
(see p.7/p.8
No. 30)
Note: The set of FID jumpers are only for advanced users to adjust the multiplier of CPU. Please
follow the table below to adjust the multiplier of CPU. However, the system will work well
without the adjustment of multiplier. You do not have to adjust the multiplier for normal
usage.
Multiplier
FID0
FID1
FID2
FID3
FID4
5x
1-2
1-2
2-3
1-2
1-2
5.5x
2-3
1-2
2-3
1-2
1-2
6x
1-2
2-3
2-3
1-2
1-2
6.5x
2-3
2-3
2-3
1-2
1-2
7x
1-2
1-2
1-2
2-3
1-2
7.5x
2-3
1-2
1-2
2-3
1-2
8x
1-2
2-3
1-2
2-3
1-2
8.5x
2-3
2-3
1-2
2-3
1-2
9x
1-2
1-2
2-3
2-3
1-2
9.5x
2-3
1-2
2-3
2-3
1-2
10x
1-2
2-3
2-3
2-3
1-2
10.5x
2-3
2-3
2-3
2-3
1-2
11x
1-2
1-2
1-2
1-2
1-2
11.5x
2-3
1-2
1-2
1-2
1-2
12x
1-2
2-3
1-2
1-2
1-2
12.5x
2-3
2-3
1-2
1-2
1-2
13x
1-2
1-2
2-3
1-2
2-3
13.5x
2-3
1-2
2-3
1-2
2-3
14x
1-2
2-3
2-3
1-2
2-3
15x
1-2
1-2
1-2
2-3
2-3
16x
1-2
2-3
1-2
2-3
2-3
16.5x
2-3
2-3
1-2
2-3
2-3
17x
1-2
1-2
2-3
2-3
2-3
18x
2-3
1-2
2-3
2-3
2-3
19x
2-3
1-2
1-2
1-2
2-3
20x
2-3
2-3
1-2
1-2
2-3
21x
2-3
2-3
2-3
1-2
2-3
22x
2-3
1-2
1-2
2-3
2-3
23x
1-2
2-3
2-3
2-3
2-3
24x
2-3
2-3
2-3
2-3
2-3
1
1
1
1
1
FID0
FID1
FID2
FID3
FID4