Adaptec 1520A User Guide - Page 37
Termination for Internal Devices Only
View all Adaptec 1520A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
Hardware Installation The table below shows how termination must be set on the host adapter for the three possible configurations of devices on the SCSI bus. If you need to change the termination setting, follow the instructions in Terminating the SCSI Bus on page 3-2. Devices Connected to Host Adapter Internal devices only (host adapter at end of cable) External devices only (host adapter at end of cable) Internal and external devices (host adapter in the middle) Host Adapter Terminators All three installed All three installed All three removed The following sections explain each of the three configurations. Termination for Internal Devices Only When only internal devices are connected to the host adapter, the last device connected to the ribbon cable should be terminated and the host adapter should be terminated, as shown in Figure 3-2. Internal device No termination Internal device Termination enabled Host adapter Terminators installed Figure 3-2. Connecting Internal Devices Only 3-3 AAAAAAAAAAAAAAAAAASPCAAAAAArtuHoiAAArncAAAArtkAAAe-SAAAn1NAAApt5AAAeuD1AAAcmAAA0aAAANtAbeAAAeu:/AAAr2mAAA1:0AAA15bAAAA/1eAAA1rAAA0S8:AAA4/e4AAA90rAAA94i0eAAA1-AAAs08AAAU04AAA,2AAAsR-AAAe0AAAre0'AAAvsAAA.AAAGCAAAuAAAAAAidAAAeAAAAAAAAAEAAACAAAAAANAAAAAADAAAAAAaAAAtAAAeAAA:PAAA1aAAA1AAAg/AAAe2AAA:9AAA3/AAA9-AAA43AAAAAAAAAAAAAAAAAAAA